Final | 4/4/2018 | 4/5/2018 | 4/5/2018 | P | PASS |
Ben Livingston
|
|
|
Access #1993 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
|
Rough-in | 1/18/2018 | 1/19/2018 | 1/19/2018 | A | PASS |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
|
Pressure Test | 1/18/2018 | 1/19/2018 | 1/19/2018 | A | PASS |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN 20lb gas, 5lb flue x2
|
Issue PAID IN FULL permit | | | 1/11/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/11/2018 | | DONE |
|
|
|
This permit was created on the web by GREGORY ANDERSEN
|