Final | 4/10/2018 | 4/10/2018 | 4/10/2018 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- fireplace and final ok
|
Final | 4/9/2018 | 4/9/2018 | 4/9/2018 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- need to firecaulk outside air at ceiling in garage and insulate- flexible b vent \needs 1" clearance to PVC flue- pvc flue needs fire caulked- dryer vent vent needs sealed in laundry room at floor in box- b vent needs fire caulked at ceiling in garage- left correction notice on filter clip in garage
|
Pressure Test | 2/5/2018 | 2/6/2018 | 2/6/2018 | A | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- already witnessed this test
|
Rough-in | 2/5/2018 | 2/6/2018 | 2/6/2018 | A | PASS |
Brian Scoles
|
|
|
FP inspection also please Phone #: ###-#### Inspection requested via web by dannyel chaloupka- R/I ok- fireplace R/I ok
|
Rough-in | 2/5/2018 | 2/6/2018 | 2/5/2018 | A | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
|
Rough-in | 1/30/2018 | 1/30/2018 | 1/30/2018 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- fresh air needs to be ran in 6" round pipe per manual J and insulated in attic and garage- missing 14x4 transfer opening master bedroom first floor- need all framing completed in closet 2nd floor, laundry room and garage- left correction notice front window
|
Pressure Test | 1/30/2018 | 1/30/2018 | 1/30/2018 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
|
Conference | 1/29/2018 | 1/30/2018 | 1/30/2018 | P | PASS |
Brian Scoles
|
|
|
witness d blast 115 pm Phone #: ###-#### Inspection requested via web by dannyel chaloupka- duct blast test pass
|
Rough-in | 1/29/2018 | 1/30/2018 | 1/30/2018 | A | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
|
Pressure Test | 1/29/2018 | 1/30/2018 | 1/30/2018 | A | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
|
Rough-in | 1/26/2018 | 1/29/2018 | 1/29/2018 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- need approved manual J onsite
|
Pressure Test | 1/26/2018 | 1/29/2018 | 1/29/2018 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- gas below 20 psi
|
Issue PAID IN FULL permit | | | 1/15/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/15/2018 | | DONE |
|
|
|
This permit was created on the web by Debbie Marino
|