Final | 5/3/2018 | 5/4/2018 | 5/4/2018 | A | PASS |
Jack Reynolds
|
|
|
Garage code #1234 Phone #: ###-#### Inspection requested via web by Debbie Marino -final ok
|
Conference | 4/9/2018 | 4/11/2018 | 4/11/2018 | P | PASS |
Brian Scoles
|
|
|
w duct blast 1230 pm Phone #: ###-#### Inspection requested via web by dannyel chaloupka- duct blast test pass
|
Rough-in | 3/7/2018 | 3/8/2018 | 3/8/2018 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- R/I ok
|
Pressure Test | 3/7/2018 | 3/8/2018 | 3/8/2018 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
|
Rough-in | 3/6/2018 | 3/7/2018 | 3/7/2018 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- gas test fail- b vent insulation shild at water heater locstion needs 1" clearance and secured- exhaust fans need sealed where 90 degree attaches to fan- need ladder to access furnace in attic- need nail plates on condensate drain at ceiling location- correction notice in front window
|
Pressure Test | 3/6/2018 | 3/7/2018 | 3/7/2018 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- gauge at 3psi
|
Issue PAID IN FULL permit | | | 2/15/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/15/2018 | | DONE |
|
|
|
This permit was created on the web by Debbie Marino
|