Final | 5/8/2018 | 5/8/2018 | 5/8/2018 | P | PASS |
Brian Scoles
|
|
|
Final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok
|
Rough-in | 4/19/2018 | 4/20/2018 | 4/20/2018 | A | PASS |
Brian Scoles
|
|
|
re-inspection for rough Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok
|
Final | 4/18/2018 | 4/19/2018 | 4/19/2018 | A | FAIL |
Brian Scoles
|
|
|
final - call David Phone #: ###-#### Inspection requested via web by Brandon Sorensen- Left correction notice on furnace 1. need drip leg between shut off valves and furnace/water heater 2.need three screws on water heater vent 3.need uv protection on line set outside 4.where line set enters indoor coil rubber groment needs placed on coil. Also need to seal coil to furnace on the front side. 5.seal hole where line set enters house and where gas line enters the house 6. seal dryer vent where it goes through the floor
|
Rough-in | 3/14/2018 | 3/15/2018 | 3/15/2018 | A | PASS |
Brian Scoles
|
|
|
rough-in call David Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok
|
Rough-in | 3/12/2018 | 3/13/2018 | 3/13/2018 | A | FAIL |
Brian Scoles
|
|
|
rough in - call david with any questions Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need approved ACCA report onsite to do inspection- need to wrap inert tape thru wall penetration on gas line at meter location
|
Pressure Test | 3/12/2018 | 3/13/2018 | 3/13/2018 | A | PASS |
Brian Scoles
|
|
|
pressure test - call david with questions Phone #: ###-#### Inspection requested via web by Brandon Sorensen- 20lb gas pass
|
Issue PAID IN FULL permit | | | 3/9/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/9/2018 | | DONE |
|
|
|
This permit was created on the web by Brandon Sorensen
|