Final | 10/23/2018 | 10/29/2018 | 10/29/2018 | A | PASS |
Brian Scoles
|
|
|
Please call us when you are on your way so we can notify customer. Thank you! Phone #: ###-#### Inspection requested via web by Dan McFate- furnace co ok
|
Final | 3/27/2018 | 3/28/2018 | 3/28/2018 | P | FAIL |
Brian Scoles
|
|
|
Please call when you are on the way so we can meet you there Phone #: ###-#### Inspection requested via web by Dan McFate- double wall b vent can not go into single wall pipe then back to b vent- need to check existing b vent to make sure its still intact on inside, might need to be replaced- single wall pipe needs 6" clearance to combustibles
|
Final | 3/22/2018 | 3/23/2018 | 3/23/2018 | P | CANC |
Brian Scoles
|
|
|
Please call when you are on the way so we can meet you there Phone #: ###-#### >> Inspection requested via web by Dan McFate Inspection cancelled from web by: Dan McFate
|
Issue PAID IN FULL permit | | | 3/19/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/19/2018 | | DONE |
|
|
|
This permit was created on the web by Dan McFate
|