Final | 7/18/2018 | 7/19/2018 | 7/19/2018 | A | PASS |
Brian Scoles
|
|
|
Final Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
|
Final | 7/16/2018 | 7/17/2018 | 7/17/2018 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- need uv protection on lineset at condenser
|
Conference | 6/15/2018 | 6/18/2018 | 6/18/2018 | A | PASS |
Brian Scoles
|
|
|
Blast witness at 9:30 please. Questions please call Randy ###-#### Phone #: ###-#### Inspection requested via web by Randy Hart- duct blast test pass
|
Conference | 6/14/2018 | 6/15/2018 | 6/15/2018 | A | CANC |
Brian Scoles
|
|
|
Blast witness at 9:30 Please. Questions please call Randy ###-#### Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
Conference | 6/6/2018 | 6/7/2018 | 6/6/2018 | A | CANC |
Brian Scoles
|
|
|
Blast Witness at 10 am Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
Conference | 6/6/2018 | 6/6/2018 | 6/6/2018 | A | CANC |
Brian Scoles
|
|
|
10AM Blast witness please. Questions please call Randy ###-#### Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
Conference | 5/29/2018 | 5/29/2018 | 5/29/2018 | A | FAIL |
Brian Scoles
|
|
|
Blast witness at 9:30 Please Phone #: ###-#### Inspection requested via web by Randy Hart- needs work
|
Rough-in | 5/18/2018 | 5/21/2018 | 5/21/2018 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- R/I ok
|
Rough-in | 5/16/2018 | 5/17/2018 | 5/17/2018 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- b vent in garage needs 1" clearance to combustibles need to remove part of 2x4 nailer at ceiling- exhaust fans (all) need sealed/taped at fan to galv- b vent in needs firestop installed and insulation shield needs to go to roof and firecaulk at floor missing- need to firecaulk R/A duct at ceiling and floor in chase- left correction notice front window
|
Rough-in | 5/16/2018 | 5/16/2018 | 5/16/2018 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- need approved ACCA report onsite for inspection
|
Pressure Test | 5/16/2018 | 5/16/2018 | 5/16/2018 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass
|
Issue PAID IN FULL permit | | | 5/14/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 5/14/2018 | | DONE |
|
|
|
This permit was created on the web by Randy Hart
|