Final | 10/9/2018 | 10/10/2018 | 10/10/2018 | A | PASS |
Jack Reynolds
|
|
|
Duct blast witness a 8am, thanks 101-102-201-202-301-302 Phone #: ###-#### Inspection requested via web by Gary Reeves- units 01&02 duct blast ok- final ok- signed card for permanent occupancy
|
Final | 9/26/2018 | 9/28/2018 | 9/28/2018 | A | PART |
Jack Reynolds
|
|
|
duct blast tests at 8 thanks 103,104,203,204,303,304 Phone #: ###-#### Inspection requested via web by Gary Reeves -03/04 final ok signed card for 03/04 occupancy
|
Final | 9/21/2018 | 9/21/2018 | 9/21/2018 | P | PART |
Jack Reynolds
|
|
|
105,106,205,206,305,306 Phone #: ###-#### Inspection requested via web by Gary Reeves - corrections on 05/06 ok- occupancy of 05/06 units ok
|
Final | 9/18/2018 | 9/18/2018 | 9/18/2018 | P | FAIL |
Jack Reynolds
|
|
|
105,106,205,206,305,306 Phone #: ###-#### Inspection requested via web by Gary Reeves- all duct blasts ok- 106 has a hole in the return duct work that needs sealed- back draft damper outside is broken- 205- lineset insulation needs fixed and a transfer grille is missing- 206 lineset insulation needs fixed- 305 lineset insulation needs fixed-
|
Final | 9/17/2018 | 9/18/2018 | 9/18/2018 | A | CANC |
Jack Reynolds
|
|
|
105,106,205,206,305,306 Phone #: ###-#### Inspection requested via web by Gary Reeves - rescheduled for PM
|
Final | 9/5/2018 | 9/6/2018 | 9/7/2018 | A | PART |
Jack Reynolds
|
|
|
107,108,207,208,307,308 Phone #: ###-#### Inspection requested via web by Gary Reeves - duct blast on 107,108,307,308 ok- air balance on all ok- line sets need a little work outdoors (support)- 307 needs a pan switch - occupancy ok on 107,108,207,208,307,308
|
Final | 9/4/2018 | 9/5/2018 | 9/5/2018 | A | CANC |
Jack Reynolds
|
|
|
107,108,207,208,307,308 Phone #: ###-#### Inspection requested via web by Gary Reeves - rescheduled ductblast and finals
|
Rough-in | 7/30/2018 | 7/31/2018 | 7/31/2018 | A | PART |
Jack Reynolds
|
|
|
Please Re-inspect 104-204-303-304 . thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
|
Rough-in | 7/27/2018 | 7/30/2018 | 7/30/2018 | A | FAIL |
Jack Reynolds
|
|
|
please inspect 103,104,203,204,303,304 Phone #: ###-#### Inspection requested via web by Gary Reeves 104- duct seal on return at furnace 204- supply flex being smashed in mech room- return pipe needs sealed at end cap- supply duct needs sealed at end cap 303- supply flex run needs fixed its being smashed - return end cap also needs to be sealed 304- supply run into living room needs support strap adjusted as to not smash flex
|
Rough-in | 7/25/2018 | 7/26/2018 | 7/26/2018 | A | PART |
Jack Reynolds
|
|
|
Please Inspect: 101,102,201,203,301,302 Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
|
Rough-in | 7/24/2018 | 7/25/2018 | 7/25/2018 | P | FAIL |
Jack Reynolds
|
|
|
please inspect: 101,102,201,202,301,302 Phone #: ###-#### Inspection requested via web by Gary Reeves- 101 flex ducting needs strapped up/ supported -201 lineset needs supported -flex runs are being smashed by framing- flex runs need supported/ strapped up -202 flex runs need supported/ strapped up- some flex runs have large sags in them -302 a few flex runs are being smashed by their supports
|
Rough-in | 7/24/2018 | 7/25/2018 | 7/24/2018 | A | CANC |
Jack Reynolds
|
|
|
please Inspect 101,102,201 202, 301,302 Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
Rough-in | 7/11/2018 | 7/12/2018 | 7/12/2018 | A | PART |
Jack Reynolds
|
|
|
Please Inspect 105,106,205,206,305,306 Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
|
Rough-in | 7/11/2018 | 7/12/2018 | 7/11/2018 | P | CANC |
Jack Reynolds
|
|
|
Please Inspect: 105,106,205,206,305,306 Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
Rough-in | 7/11/2018 | 7/11/2018 | 7/11/2018 | P | CANC |
Jack Reynolds
|
|
|
please inspect: 105,106,205,206,305,306 Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
Rough-in | 7/10/2018 | 7/10/2018 | 7/10/2018 | P | NR |
Jack Reynolds
|
|
|
105and 106 crawl not ready- some flex runs need supported- flex duct being smashed- line set insulation needs repaired and needs nail plates at floor-205 and 206 one lineset needs fire caulked at floor- some duct sealing needs finished- duct work is being smashed by ceiling and some flex runs need support- 305 and 306 flex duct needs rerouted and supports need adjusted flex ducting should be ran free or kinks or smashes and free flowing bends
|
Rough-in | 7/9/2018 | 7/10/2018 | 7/10/2018 | P | CANC |
Jack Reynolds
|
|
|
please inspect 105,106,205,206,305 and 306 Phone #: ###-#### Inspection requested via web by Gary Reeves-
|
Rough-in | 6/28/2018 | 6/29/2018 | 6/29/2018 | A | PASS |
Jack Reynolds
|
|
|
107,108,207,208,307,308 Phone #: ###-#### Inspection requested via web by Gary Reeves- this included the dryer vents- R/I ok
|
Rough-in | 6/28/2018 | 6/28/2018 | 6/28/2018 | P | FAIL |
Jack Reynolds
|
|
|
107,108,207,208,307,308 Phone #: ###-#### Inspection requested via web by Gary Reeves 107- return needs sealed- linesets down wall need to be repaired and tape 108- linesets need to be repaired and taped 207- supply tap needs more duct seal- 4" run into walk-in closet is sagging and needs support- supply trunk in bathroom is being kinked by the ceiling framing 208- linesets need repaired and taped- supply run in hallway is kinked reposition support- liquid line on line set is touching the metal framing studs 307- supply run into dinning room has a large sag 308- supply run into the master room has a kink reposition support- supply run into bedroom 2 has a kink reposition support
|
Rough-in | 6/26/2018 | 6/27/2018 | 6/27/2018 | P | FAIL |
Jack Reynolds
|
|
|
107,108,207,208,307,308 Phone #: ###-#### Inspection requested via web by Gary Reeves -107&108 need framing around ducts- need to fix all lineset insulation- 107 needs some duct sealing finished- 207&208 are not ready worker was still working on finishing boots- lineset insulation needs rips fixed- 307&308 needs lineset supported every 6'- also needs insulation fixed- every floor has work to still be done go through all units check work and when framing is done downstairs call in for R/I inspection
|
Hold | | | 6/26/2018 | | DONE |
|
|
|
NEED FULL FIXTURE COUNT-done
|
Telephone call | | | 6/25/2018 | | DONE |
|
|
|
customer called and we changed address from 3022 to 3030
|
Telephone call | | | 6/25/2018 | | DONE |
|
|
|
talked to Legands-she will call back with a fixture count-address has been fixed
|
Issue PAID IN FULL permit | | | 6/4/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/1/2018 | | DONE |
|
|
|
This permit was created on the web by Gary Reeves
|
First Notice | 10/10/2018 | 10/10/2018 | | | |
Jack Reynolds
|
|
|
|