Final | 10/3/2018 | 10/4/2018 | 10/4/2018 | A | PASS |
Jack Reynolds
|
|
|
duct blast witness with logan at 8 am. Phone #: ###-#### Inspection requested via web by Gary Reeves- duct blast ok- final ok
|
Rough-in | 7/9/2018 | 7/9/2018 | 7/9/2018 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
|
Pressure Test | 7/9/2018 | 7/9/2018 | 7/9/2018 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 5lb flue ok- 20 lb gas ok
|
Rough-in | 7/6/2018 | 7/9/2018 | 7/9/2018 | A | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves -water heater flue in attic needs 1" clearances(flex duct is touching flue)- supply runs into master room, master bath, and bedroom 3 are being pinched by supports. need to adjust flex for a free flowing run to boots- supply trunk in attic needs duct seal at Y - 5lb flue pressure test fail gauge wont zero
|
Pressure Test | 7/6/2018 | 7/9/2018 | 7/9/2018 | A | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 5lb flue pressure test fail need to see gauge zero( replace gauage ) 20lb gas pressure ok
|
Issue PAID IN FULL permit | | | 6/29/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/29/2018 | | DONE |
|
|
|
This permit was created on the web by Gary Reeves
|