Final | 8/13/2018 | 8/13/2018 | 8/13/2018 | A | PASS |
Brian Scoles
|
|
|
|
Pressure Test | 8/9/2018 | 8/13/2018 | 8/13/2018 | A | PASS |
Brian Scoles
|
|
|
For gas range Phone #: ###-#### Inspection requested via web by Mike Pearson- 20lb gas pass to range
|
Pressure Test | 8/7/2018 | 8/8/2018 | 8/8/2018 | A | FAIL |
Brian Scoles
|
|
|
900 to 930am- 208- ###-####- gauge wont zero out- at no point can 1 shut off valve have gas on one side and air on other- need to install 2 shutoff valves with open tee between them and use as a sediment trap- leave sediment trap out until after pressure test is completed
|
Pressure Test | 8/1/2018 | 8/3/2018 | 8/3/2018 | P | NH |
Brian Scoles
|
|
|
Above phone number is home owner, Chris Lewis. Contractor is, mike with driven mechanical llc ###-#### Phone #: ###-#### Inspection requested via web by Mike Pearson- no one home- called homeowner he wasnt home- will reschedule when someone is home
|
Issue PAID IN FULL permit | | | 7/30/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/30/2018 | | DONE |
|
|
|
This permit was created on the web by Mike Pearson
|