Final | 11/2/2018 | 11/5/2018 | 11/5/2018 | A | PASS |
Brian Scoles
|
|
|
Please inspect in the AM. Andy ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|
Final | 10/31/2018 | 11/2/2018 | 11/2/2018 | A | CANC |
Brian Scoles
|
|
|
Please inspect in the AM. No garage code yet, the key is in the outlet by the front door. Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
|
Rough-in | 9/13/2018 | 9/14/2018 | 9/14/2018 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Krista Boss- R/I ok- need to fix all arma flex in crawl on lineset by final
|
Pressure Test | 9/13/2018 | 9/14/2018 | 9/14/2018 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Krista Boss- 20lb gas pass
|
Rough-in | 9/12/2018 | 9/13/2018 | 9/13/2018 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Krista Boss- need approved manual J onsite- all register boots in floor and ceiling need to be sealed inside and to floor- gas piping outside wall in garage- insulation shield on water heater flue needs 1" clearance- need to seal 6" round pipe for range hood in wall(stub out into cabinets)
|
Pressure Test | 9/12/2018 | 9/13/2018 | 9/13/2018 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Krista Boss- gas piping in garage wall is outside wall- piping needs to be inside wall- retest gas when fixed-
|
Issue PAID IN FULL permit | | | 8/31/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/30/2018 | | DONE |
|
|
|
This permit was created on the web by Krista Boss
|