Permit NumberMEC18-05418
StatusFinaled
Name LEGENDS MECHANICAL LLC
Site Address 4424 W EMERALD ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: complete hvac install
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/17/201910/18/201910/18/2019PPASS
DetailsJack Reynolds
Key is in the outlet cover by the front door Phone #: ###-#### Inspection requested via web by Gary Reeves
- final ok
Final8/8/20198/9/20198/9/2019ACANC
DetailsJack Reynolds
Duct Blast witness @ 9am Phone #: ###-#### Inspection requested via web by Gary Reeves
- duct blast ok
Conference8/9/20198/9/20198/9/2019APASS
DetailsJack Reynolds
Duct Blast witness @ 9am Phone #: ###-#### Inspection requested via web by Gary Reeves
- duct blast ok
Final6/12/20196/13/20196/13/2019PNR
DetailsJack Reynolds
Duct blast with Jay @ 3PM. Thanks Phone #: ###-#### Inspection requested via web by Gary Reeves
- no power to house yet contractor will reschedule
Pressure Test12/13/201812/14/201812/14/2018PPASS
DetailsJack Reynolds
Inspection requested via web by Gary Reeves
- 20lb gas pressure test ok
- 5lb flue pressure test ok
Rough-in12/13/201812/14/201812/14/2018PPASS
DetailsJack Reynolds
Inspection requested via web by Gary Reeves
- R/I ok
Rough-in12/11/201812/12/201812/12/2018PFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Gary Reeves
- water heater flue needs 1" clearances
- insulation sheild needs needs to maintain 1" clearances
- need Man J approved and onsite
- combustion air for mec room
Pressure Test12/11/201812/12/201812/12/2018PFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Gary Reeves
- gauge under 20lb
Issue PAID IN FULL permit  11/9/2018 DONE
Payment received via Govolutions
Application received  11/9/2018 DONE
This permit was created on the web by Gary Reeves