Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberMEC18-05608
StatusFinaled
Name WESTERN HEATING & A/C
Site Address 3061 N LINDA VISTA LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: IN NEW HOME, INSTALL HVAC
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/26/20196/26/20196/26/2019PPASS
DetailsBrian Scoles
GARAGE DOOR OPEN (UNLOCKED NO CODE) Phone #: ###-#### Inspection requested via web by Aaron Alandt-
Final6/19/20196/19/20196/19/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Aaron Alandt- need duct blast test performed on upstairs furnace- need to seal lineset penetration outside at a/c
Rough-in12/14/201812/14/201812/14/2018PPASS
DetailsBrian Scoles
Builder asked me to re-call without the framing around the ductwork in the stairwell. He wants the framer to frame around that when they come back to do to the framing corrections. Ival spoke with Troy about the singular fresh air to the upstairs unit. The furnace upstairs was changed out. Inspection requested via web by Aaron Alandt- R/I ok- builder will be responsible for framing in stair well area
Rough-in12/6/201812/7/201812/7/2018AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace 2nd floor doesnt match man j model number need to resubmit with equipment installed or install right furnace- dryer vent exceeds 35 feet max length need to reroute 2nd floor- all registers need sealed on inside supply and r/a cans- 6" fresh air cant come from roof 2nd floor- bath #3 needs moved to location on man j theres a slider door being installed-condensate need ran not sure whats going on with them 2nd floor- range duct in garage is below joists- all ducts need sealed in basement registers and square duct all floors lots partially done- need 6" fresh air to downstairs furnace- need condesate ran to outide downstairs not sure where it will be going no floor sink to drain to, needs to be ran in 3/4 pvc- correction notice left front window
Pressure Test12/6/201812/7/201812/7/2018APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass- 5lb flue for downstair furnace and upstairs water heater pass
Issue PAID IN FULL permit  11/19/2018 DONE
Payment received via Govolutions
Application received  11/19/2018 DONE
This permit was created on the web by Aaron Alandt