Final | 7/24/2019 | 7/24/2019 | 7/24/2019 | P | PASS |
Jack Reynolds
|
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney - final ok
|
Final | 7/23/2019 | 7/24/2019 | 7/24/2019 | A | PART |
Jack Reynolds
|
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney - fireplace finish materials and mantel ok - general contractor needs to pull mech permit for range that is installed. Contractor says he will be working on pulling this permit today. - range venting ok
|
Final | 7/18/2019 | 7/19/2019 | 7/19/2019 | P | PART |
Jack Reynolds
|
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney - range vent needs a mechanical permit pulled - need installation specs for fireplace to check finish materials clearances - furnace ac coil exhaust fans dryer vent etc ok
|
Final | 7/17/2019 | 7/18/2019 | 7/18/2019 | P | FAIL |
Jack Reynolds
|
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney - line set penetration needs sealed - secondary drain needs a wet switch - looks like a range hood will be installed and needs a vent ran vertically not sure if GC will have you guys perform that work or not - talked with the GC about existing fireplace and clearances to face materials this is another item that is not your work just noting it for future reference
|
Pressure Test | 6/18/2019 | 6/18/2019 | 6/18/2019 | P | PASS |
Jack Reynolds
|
|
|
Field Super: Daryl Thomas requesting a FLU PRESSURE WITNESS. Phone #: ###-#### Inspection requested via web by Lisa Whitney - 5lb flue test on furnace ok
|
Rough-in | 4/15/2019 | 4/15/2019 | 4/15/2019 | P | PASS |
Jack Reynolds
|
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney - 5lb flue pressure test ok - R/I ok
|
Pressure Test | 3/14/2019 | 3/14/2019 | 3/14/2019 | P | PASS |
Jack Reynolds
|
|
|
field super: Daryl Thomas DOOR CODE 6673 Phone #: ###-#### Inspection requested via web by Lisa Whitney - 20lb gas pressure test ok for new tankless water heater done by plumber - by the next inspection need to have permit updated with all items being worked on gas line, 5 bathroom fans, dryer vent, water heater vent - will also need to see a 5lb flue pressure test
|
Issue PAID IN FULL permit | | | 1/4/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/4/2019 | | DONE |
|
|
|
This permit was created on the web by Lisa Whitney
|