Final | 3/27/2020 | 3/30/2020 | 3/30/2020 | A | PASS |
Jack Reynolds
|
|
|
please call Dennis prior to going to the job site.
Thanks Phone #: ###-#### Inspection requested via web by Dennis Fox - corrections and updated man J ok - final ok
|
Mec-Aging Inspection | 2/4/2020 | 2/4/2020 | 2/4/2020 | | PASS |
Jack Reynolds
|
|
|
WIP
|
Conference | 11/5/2019 | 11/5/2019 | 11/5/2019 | P | DONE |
Chad Schwendiman
|
|
|
2:30 - Went by with the other trade inspector/supervisors and met with the homeowner. I gave her a correction notice stating the following. 1. Need to remove the supply grills from the floor of the shower and relocte a minimum of 6 feet above the floor. 2. Need to remove return grill from shower room. 3. Need to remove ducted return grill from bedroom with toilet open to to the room. (transfer grill okay). 4. Need to submit a new manual J showing the changes. 5. Need to submit new architectural drawings to plan review for approval.
|
Conference | 10/30/2019 | 10/30/2019 | 10/30/2019 | A | DONE |
Chad Schwendiman
|
|
|
11:00 am - Had another inspector report that there could possibly be issues with the HVAC install on this project. I reopened the permit and went and met the mechanical contractor and the owner on site. They have turned the sunroom into a shower room. currently there is supply grills installed on the floor and a return grill in the room. I explained to them that we can't have the floor registers in the shower area, and we need to remove the return grill from the shower. they are looking at a couple diffrent options to try to seperate the shower area from the rest of the room. additionally they have a ducted return grill in the bedroom where they have built a bathroom without seprrating it from the bedroom so I explained to them that we can't pull ducted return air from the room because of the bathroom. They are looking at the redesign options available to them. I instructed them to have new drawings submitted to the city of Boise.
|
CHANGE STATUS TO (ISS) | | | 10/29/2019 | | DONE |
|
|
|
Re-issued permit do to changes from original design. Chad S.
|
Final | 7/21/2019 | 7/22/2019 | 7/22/2019 | P | PASS |
Jack Reynolds
|
|
|
Please call Dennis before going to the job site for access. Phone #: ###-#### Inspection requested via web by Dennis Fox - final ok
|
Rough-in | 5/1/2019 | 5/2/2019 | 5/2/2019 | A | PASS |
Jack Reynolds
|
|
|
Please call prior to going to the job site.
Thanks, Dennis Fox Phone #: ###-#### Inspection requested via web by Dennis Fox - R/I ok - check Man J. at final
|
Issue PAID IN FULL permit | | | 1/30/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/30/2019 | | DONE |
|
|
|
This permit was created on the web by Dennis Fox
|