Final | 4/15/2019 | 4/15/2019 | 4/15/2019 | P | PASS |
Jack Reynolds
|
|
|
Call Brian C at ###-#### when in route Phone #: ###-#### Inspection requested via web by Sabrina DeHority - furnace ac coil co ok
|
Pressure Test | 4/15/2019 | 4/15/2019 | 4/15/2019 | P | PASS |
Jack Reynolds
|
|
|
Call Brian C at ###-#### when in route Phone #: ###-#### Inspection requested via web by Sabrina DeHority - 20lb gas pressure test ok
|
Final | 4/15/2019 | 4/16/2019 | 4/15/2019 | A | CANC |
Jack Reynolds
|
|
|
Please call Corey at ###-#### when in route Phone #: ###-#### >> Inspection requested via web by Sabrina DeHority Inspection cancelled from web by: Sabrina DeHority
|
Pressure Test | 4/15/2019 | 4/16/2019 | 4/15/2019 | A | CANC |
Jack Reynolds
|
|
|
Please call Corey at ###-#### when in route Phone #: ###-#### >> Inspection requested via web by Sabrina DeHority Inspection cancelled from web by: Sabrina DeHority
|
Final | 4/10/2019 | 4/11/2019 | 4/11/2019 | A | FAIL |
Jack Reynolds
|
|
|
Home is vacant - key will be under the mat Phone #: ###-#### Inspection requested via web by Sabrina DeHority - furnace b vent needs 1" clearances at roof line - gasline in attic needs supported and sediment trap needs to be after shut off valve - need to see disconnect for furnace in attic and a light with a switch at the access door - pressure test fail - line set needs UV protection - condensate line outside needs supported - need to see electrical permit pulled by others for work being done
|
Pressure Test | 4/10/2019 | 4/11/2019 | 4/11/2019 | A | FAIL |
Jack Reynolds
|
|
|
Home is vacant - key will be under the mat Phone #: ###-#### Inspection requested via web by Sabrina DeHority - gauge was at zero
|
Issue PAID IN FULL permit | | | 3/25/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/25/2019 | | DONE |
|
|
|
This permit was created on the web by Sabrina DeHority
|