Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberMEC19-01610
StatusFinaled
Name T & T HEATING & COOLING
Site Address 7957 W CAMAS ST
Project Name 
Customer Number1
ePlanReviewNo
Description
Gas Piping/Pressure Test ONLY: Gas pipe install for a Unit heater.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/20/20196/21/20196/21/2019APASS
DetailsChad Schwendiman
Heath Phone #: ###-####
Rough-in4/22/20194/23/20194/23/2019APASS
DetailsBrian Scoles
Heath Phone #: ###-####- R/I ok- call in final when unit heaters installed
Pressure Test4/19/20194/19/20194/19/2019PPASS
DetailsBrian Scoles
Just a gas line pressure test witness for a unit heater. Super simple. Phone #: ###-#### Inspection requested via web by Heath Taylor- 20lb gas pass- tagged gas line
Rough-in4/19/20194/19/20194/19/2019PFAIL
DetailsBrian Scoles
Just a gas line pressure test witness for a unit heater. Super simple. Phone #: ###-#### Inspection requested via web by Heath Taylor- need csst approved nail plates from manufacture at top plate and fire blocking in wall- need inert tape on penetration thru building wall- whos doing unit heater install?- drip leg on gas line needs to be after shtoff valve and between appliance- b vent doesnt have 1" clearance at roof and needs an insulation shield installed- unit heater needs added to this permit if you did work
Issue PAID IN FULL permit  4/19/2019 DONE
Payment received via Govolutions
Application received  4/19/2019 DONE
This permit was created on the web by Heath Taylor