Final | 9/19/2019 | 9/19/2019 | 9/19/2019 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Aaron Toomey- final ok
|
Rough-in | 6/25/2019 | 6/25/2019 | 6/25/2019 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Aaron Toomey- R/I ok
|
Pressure Test | 6/25/2019 | 6/25/2019 | 6/25/2019 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Aaron Toomey- 5lb flue pass- 20lb gas already passed
|
Rough-in | 6/24/2019 | 6/24/2019 | 6/24/2019 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Aaron Toomey - CSST gas line needs approved manufactures nail plates installed - tankless water heater vent needs to be approved materials - need to see a 5lb flue pressure test
|
Pressure Test | 6/24/2019 | 6/24/2019 | 6/24/2019 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Aaron Toomey - 20lb gas pressure test ok
|
Rough-in | 6/23/2019 | 6/24/2019 | 6/24/2019 | A | FAIL |
Jack Reynolds
|
|
|
Key is in light power box at back door Phone #: ###-#### Inspection requested via web by Aaron Toomey - need stamped man J onsite - 5lb flue pressure test fail gauge was at zero and PVC installed for vent needs to be solid core - several locations need nail plates installed for line sets - gas line needs 10 mill tape installed at penentration - range vent needs backdraft damper - 2nd systems looks like it needs finished -line set in crawl needs supported
|
Pressure Test | 6/23/2019 | 6/24/2019 | 6/24/2019 | A | FAIL |
Jack Reynolds
|
|
|
Key is in light power box at back door Phone #: ###-#### Inspection requested via web by Aaron Toomey - 5lb flue pressure test fail gauge was at zero - tankless water heater vent needs to be ran in solid core PVC - re test 20lb gas after 10 mill tape is installed at penentration
|
Issue PAID IN FULL permit | | | 5/24/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 5/23/2019 | | DONE |
|
|
|
This permit was created on the web by Aaron Toomey
|