Permit Information
Permit NumberMEC19-02727
StatusFinaled
Name CREEK ENTERPRISE LLC
Site Address 8877 W ARDENE ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: COMPLETE HVAC FOR NEW HOME
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/7/201911/7/201911/7/2019PPASS
DetailsBrian Scoles
Call Dwight Van Hees for access if needed at ###-#### or Jeff Creek ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek- final ok
Final10/31/201911/1/201911/1/2019ACANC
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Andrea Creek- per phone call with Jeff- missing air balance- will reschedule
Final10/30/201910/31/201910/31/2019AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Andrea Creek
1- need locking caps on both a/c service ports
2- need airbalance report for both units onsite none found
3- need sediment trap between gas shut off valve and furnace both units
4-water heater flue in laundry room needs 6" clearance to single wall pipe from sheetrock or install b vent
5- missing R/A grill 2nd floor hallway
Rough-in7/15/20197/16/20197/16/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Andrea Creek- R/I ok- will need gable vents installed by final for combustion air from attic- need resubmitted man j onsite and approved by city at final with correct furnace installed south furnace doesnt match man j
Pressure Test7/15/20197/16/20197/15/2019PCANC
DetailsBrian Scoles
Jeff Phone #: ###-#### Inspection cancelled from web by: Andrea Creek
Rough-in7/12/20197/15/20197/15/2019PCANC
DetailsBrian Scoles
Thanks, Jeff Creek. Phone #: ###-#### >> Inspection requested via web by Andrea Creek
Rough-in7/11/20197/12/20197/12/2019AFAIL
DetailsBrian Scoles
We need both 60lb an 20lb pressure tests please. If any questions please call Jeff Creek at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek
1- need to seal all supply and retun air registers-
2- supply duct in garage joists is below joists and insulated to r8
3- fresh air can not come from register can needs to be from plenum
4- b vent in garage at ceiling needs 1" clearance to wood and attic needs draft stop installed and firecaulked
5- house needs 2 gable end vents in attic to draw combustion air from attic for laundry room
6- framing needs completed around supply/return and b vent chase and draft stop installed around supply and return ducting
7- need fresh air to upstairs downstairs unit didnt see any
8- need nail plate on dryer duct at ceiling
9- south furnace model # does not match man j need to submit whats installed 10- R/A panning in garage needsremoved and ran in pipe and insulated to r6 unconditioned space-
left notice front window
Pressure Test7/11/20197/12/20197/12/2019APASS
DetailsBrian Scoles
We need both 60lb an 20lb pressure tests please. If any questions please call Jeff Creek at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek- 60lb gas pass tagged meter- 20lb gas pass- 5lb flue pass
Issue PAID IN FULL permit  6/24/2019 DONE
Payment received via Govolutions
Application received  6/24/2019 DONE
This permit was created on the web by Andrea Creek