Final | 10/3/2019 | 10/3/2019 | 10/3/2019 | P | PASS |
Jack Reynolds
|
|
|
Michael Phone #: ###-#### - final ok
|
Final | 9/27/2019 | 9/27/2019 | 9/27/2019 | P | FAIL |
Jack Reynolds
|
|
|
Michael Phone #: ###-#### - need UL listed weather tight connectors for MC cables - range venting needs a back draft damper
|
Rough-in | 7/11/2019 | 7/11/2019 | 7/11/2019 | P | PASS |
Jack Reynolds
|
|
|
Michael Phone #: ###-#### - R/I ok
|
Override - Parcel Holds | 7/11/2019 | 1/1/1900 | 7/11/2019 | | |
|
|
|
mechanical rough in
|
Rough-in | 7/10/2019 | 7/10/2019 | 7/10/2019 | P | FAIL |
Jack Reynolds
|
|
|
Michael- please call for access. Phone #: ###-#### - gas line to range upstairs still needs proper striker plates installed. gas line is less than 2" away from stud edge
|
Override - Parcel Holds | 7/10/2019 | 1/1/1900 | 7/10/2019 | | |
|
|
|
Mechanical inspection has nothing to do with the parcel hold, it only applies to building permit.
|
Pressure Test | 7/9/2019 | 7/9/2019 | 7/9/2019 | P | PASS |
Jack Reynolds
|
|
|
20lb gas pressure test ok
|
Pressure Test | 7/9/2019 | 7/9/2019 | 7/9/2019 | P | FAIL |
Jack Reynolds
|
|
|
Michael Phone #: ###-#### - condensate line in dinning room needs nail plates - gas flex needs full striker plates installed and a protective sleeve installed at the water heater location
|
Override - Parcel Holds | 7/9/2019 | 1/1/1900 | 7/9/2019 | | |
|
|
|
mechanical inspection has nothing to do with street light
|
Pressure Test | 7/6/2019 | 7/8/2019 | 7/8/2019 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Stimpson - fail gauge was under 20lb
|
Pressure Test | 7/1/2019 | 7/2/2019 | 7/2/2019 | A | FAIL |
Jack Reynolds
|
|
|
Rough in and gas pressure test Phone #: ###-#### Inspection requested via web by Michael Stimpson - gas pressure test fail need a 30lb gauge at 20lb - gas line penetration needs protective tape installed
|
Rough-in | 7/2/2019 | 7/2/2019 | 7/2/2019 | A | FAIL |
Jack Reynolds
|
|
|
Rough in and gas pressure test Phone #: ###-#### Inspection requested via web by Michael Stimpson - need man J onsite and approved by city - pressure test needs to be on a 30lb gauge and at 20lb - condensate lines need nail plates - line sets need nail plates - dryer duct needs sealed - range duct needs sealed - exhaust fan needs connected to duct
|
Issue PAID IN FULL permit | | | 6/26/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/26/2019 | | DONE |
|
|
|
This permit was created on the web by Michael Stimpson
|