Final | 11/6/2019 | 11/7/2019 | 11/7/2019 | A | PASS |
Jack Reynolds
|
|
|
PLEASE CALL APPRENTICE JAMIE @ # LISTED WHEN EN ROUTE FOR FINAL INSPECTION Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - final ok
|
Final | 10/30/2019 | 10/30/2019 | 10/30/2019 | P | FAIL |
Jack Reynolds
|
|
|
PLEASE CALL CONTRACTOR NATE @ # LISTED WHEN EN ROUTE FOR FINAL INSPECTION Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - need air balance report onsite - dryer duct needs finished sealed and supported - storm collar on water heater vent needs pulled down to roof boot
|
Rough-in | 7/22/2019 | 7/22/2019 | 7/22/2019 | P | PASS |
Jack Reynolds
|
|
|
PLEASE CALL APPRENTICE JAMIE @ # LISTED B4 HEADING OVER Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - R/I ok
|
Rough-in | 7/19/2019 | 7/19/2019 | 7/19/2019 | P | FAIL |
Jack Reynolds
|
|
|
PLEASE CALL HVAC TECH PATRICK WHEN EN ROUTE Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - Man J needs to reflect whats being installed onsite
|
Rough-in | 7/18/2019 | 7/18/2019 | 7/18/2019 | P | FAIL |
Jack Reynolds
|
|
|
ALSO NEED GAS PRESSURE TEST DONE AT SAME TIME! PLEASE CALL CONTRACTOR NATE TAYLOR @ # LISTED WHEN EN ROUTE. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - insulaion sheild needs to maintain 1" clearances - line set in crawl needs supported and insulation in wall needs repaired - supply in kitchen needs ducted out of cabinet - man J doesn't match whats installed on existing system - supply runs upstairs are said to be 6" runs not 8" - 3" water heater flue in basement needs 1" clearanes and verify 3" is big enough for water heater - gas flex in crawl needs supported - gas line penetrations needs protective tape installed
|
Pressure Test | 7/18/2019 | 7/18/2019 | 7/18/2019 | P | PASS |
Jack Reynolds
|
|
|
ALSO NEED GAS PRESSURE TEST DONE AT SAME TIME! PLEASE CALL CONTRACTOR NATE TAYLOR @ # LISTED WHEN EN ROUTE. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - 20lb gas pressure test ok - tagged meter location
|
Issue PAID IN FULL permit | | | 6/27/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/27/2019 | | DONE |
|
|
|
This permit was created on the web by SOPHIA FLEMING
|