Permit Information
Permit NumberMEC19-02831
StatusFinaled
Name IDAHO HEATING & COOLING
Site Address 10861 W CRANBERRY CT
Project Name 
Customer Number070119-2
ePlanReviewNo
Description
Complete HVAC Installation: Complete HVAC installation including gas line, range hood vent, furnace vent, dryer vent
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/12/20199/13/20199/13/2019APASS
DetailsBen Livingston
Access 5477 Phone #: ###-#### Inspection requested via web by Joe Taylor
Final9/12/20199/13/20199/12/2019ACANC
DetailsBen Livingston
Phone #: ###-#### >> Inspection requested via web by Joe Taylor Inspection cancelled from web by: Joe Taylor
Final9/10/20199/11/20199/10/2019ACANC
DetailsBrian Scoles
jOE- PLEASE CALL FOR ACCESS Phone #: ###-#### Inspection cancelled from web by: Joe Taylor
Rough-in7/12/20197/12/20197/12/2019PPASS
DetailsBrian Scoles
Add pressure test Phone #: ###-#### Inspection requested via web by Joe Taylor
Pressure Test7/12/20197/12/20197/12/2019PPASS
DetailsBrian Scoles
Add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- 20 lb gas pass tagged meter location- 5lb flue pass
Rough-in7/11/20197/12/20197/12/2019AFAIL
DetailsBrian Scoles
Add pressure test Phone #: ###-#### Inspection requested via web by Joe Taylor- need approved manual j onsite couldnt find one- few items went over with installer havent been fixed see yesterday notes
Pressure Test7/11/20197/12/20197/12/2019AFAIL
DetailsBrian Scoles
With Rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- need flue under test- 20lb gas pass
Rough-in7/11/20197/11/20197/11/2019PFAIL
DetailsBrian Scoles
Add. P test. Phone #: ###-#### Inspection requested via web by Joe Taylo- need approved man j onsite for inspection- need crawl completed- gas line into fire place needs secured- need to pan off all wood in R/A path and seal- need to fix 10" return above furenace inner liner showing- need 10 mil inert tape on gas penetration- remove hangers on csst to range and secure to floor and add nail plate bathroom side at floor
Pressure Test7/11/20197/11/20197/11/2019APART
DetailsBrian Scoles
Add. P test. Phone #: ###-#### Inspection requested via web by Joe Taylor- 20lb gas pass- need to see flue under test max 15lb gauge- will tag gas line when flue test witnessed
Issue PAID IN FULL permit  7/1/2019 DONE
Payment received via Govolutions
Application received  7/1/2019 DONE
This permit was created on the web by Joe Taylor