Final | 12/4/2019 | 12/4/2019 | 12/4/2019 | P | PASS |
Brian Scoles
|
|
|
AC: 4141 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok
|
Final | 12/3/2019 | 12/3/2019 | 12/3/2019 | P | FAIL |
Brian Scoles
|
|
|
AC:4141 Phone #: ###-#### Inspection requested via web by Gary Reeves- no corrections made
|
Final | 11/27/2019 | 12/2/2019 | 12/2/2019 | P | FAIL |
Brian Scoles
|
|
|
AC: 4141 Phone #: ###-#### Inspection requested via web by Gary Reeves- R/A and outside air need R-6 insulation and maintain 75% actual value- need to seal lineset penetration at condenser location- gas stub out for future fire pit needs hooked up to anodised riser with shutoff valve and all piping inert taped
|
Rough-in | 9/3/2019 | 9/3/2019 | 9/3/2019 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves
|
Pressure Test | 8/29/2019 | 8/30/2019 | 8/30/2019 | P | PASS |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - 20lb gas, 5lb flue
|
Rough-in | 8/29/2019 | 8/30/2019 | 8/30/2019 | P | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - Need to insulate supply duct Y in attic on 2nd floor, Need to remove kink in exhaust flex duct on bath fan on 2nd floor, Missing return transfer in study
|
Pressure Test | 7/23/2019 | 7/24/2019 | 7/24/2019 | A | PART |
Brian Scoles
|
|
|
Please inspect under ground gasline Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass underground only- ok to backfill
|
Issue PAID IN FULL permit | | | 7/23/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/23/2019 | | DONE |
|
|
|
This permit was created on the web by Gary Reeves
|