Final | 11/4/2019 | 11/4/2019 | 11/4/2019 | P | PASS |
Brian Scoles
|
|
|
call for access code // Joe Phone #: ###-####- final ok- locking caps installed
|
Final | 10/8/2019 | 10/8/2019 | 10/8/2019 | P | FAIL |
Brian Scoles
|
|
|
Joe Phone #: ###-####- need locking caps on refrigerant ports on a/c- need to remove flex ducting on range hood and run in smooth wall pipe
|
Rough-in | 7/31/2019 | 8/1/2019 | 8/1/2019 | A | PASS |
Brian Scoles
|
|
|
add p test Phone #: ###-#### Inspection requested via web by Joe Taylor- R/I ok
|
Pressure Test | 7/31/2019 | 8/1/2019 | 8/1/2019 | A | CANC |
Brian Scoles
|
|
|
add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- passed yesterday
|
Rough-in | 7/30/2019 | 7/31/2019 | 7/31/2019 | A | FAIL |
Brian Scoles
|
|
|
add p test Phone #: ###-#### Inspection requested via web by Joe Taylor- 1- gas piping in garage needs supported 2- csst gas piping in living room to range needs min 2" from bottom of truss 3- missing transfer for den per man j 4- crawl ducting needs min 4" off ground 5- need to seal all supply and R/A spot welds on all register boots 6- need to firecaulk csst gas penetration in fireplace chase 7- need more support on line set in crawl and fix rips and tears
left correction notice front window
no equipment set will check at final
|
Pressure Test | 7/30/2019 | 7/31/2019 | 7/31/2019 | A | PASS |
Brian Scoles
|
|
|
add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- 20lb gas pass tagged meter bar
|
Pressure Test | 7/30/2019 | 7/31/2019 | 7/30/2019 | P | CANC |
Brian Scoles
|
|
|
Add rough in Phone #: ###-#### >> Inspection requested via web by Joe Taylor Inspection cancelled from web by: Joe Taylor
|
Rough-in | 7/30/2019 | 7/31/2019 | 7/30/2019 | P | CANC |
Brian Scoles
|
|
|
Add p test Phone #: ###-#### >> Inspection requested via web by Joe Taylor Inspection cancelled from web by: Joe Taylor
|
Issue PAID IN FULL permit | | | 7/30/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/30/2019 | | DONE |
|
|
|
This permit was created on the web by Joe Taylor
|