Final | 11/8/2019 | 11/12/2019 | 11/12/2019 | A | PASS |
Troy James
|
|
|
call for garage code // Doris Ann Phone #: ###-####
|
Override - Parcel Holds | 11/8/2019 | 1/1/1900 | 11/8/2019 | | |
|
|
|
ok - for mec
|
Rough-in | 8/21/2019 | 8/21/2019 | 8/21/2019 | P | PASS |
Brian Scoles
|
|
|
we do not install fireplaces Phone #: ###-#### Inspection requested via web by Terek Worley
|
Rough-in | 8/19/2019 | 8/20/2019 | 8/20/2019 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- 1- fresh air pinched off at truss needs to flow smoothly reroute 2- combustion air for laundry room needs to commence with in 12" of ceiling and floor 3- bath fan master bath pinched off going thru joist reroute smoothly 4- b vent needs to be ran all the way to furnace ion attic
|
Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- 1- need ladder provided by contractor to access furnace/coil on attic 2- 6" fresh air can not be tied into R/A can has to be tied into R/A plenum near furnace and seal filter box in closet 3- framing needs completed around supply duct 2nd floor 4- bath fan for master bath 1st floor pinched off where goes thru joist 5- upper and lower combustion air for laundry room needs to commence with 12 inches of floor and ceiling
Left correction notice front entry window
|
Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass tagged meter location
|
Issue PAID IN FULL permit | | | 8/8/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/8/2019 | | DONE |
|
|
|
This permit was created on the web by Terek Worley
|