Final | 9/10/2019 | 9/10/2019 | 9/10/2019 | P | PASS |
Brian Scoles
|
|
|
keys are in electrical box Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
Rough-in | 8/26/2019 | 8/27/2019 | 8/27/2019 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt- R/I ok
|
Pressure Test | 8/26/2019 | 8/27/2019 | 8/27/2019 | A | PASS |
Brian Scoles
|
|
|
underground gas line Phone #: ###-#### Inspection requested via web by Joseph Profitt- 20lb gas pass- underground gas piping ok to back fill
|
Rough-in | 8/19/2019 | 8/20/2019 | 8/20/2019 | P | PART |
Brian Scoles
|
|
|
inspecting condensate drain and line set Phone #: ###-#### Inspection requested via web by Joseph Profitt- R/I will pass once gas line underground is fixed
|
Pressure Test | 8/19/2019 | 8/20/2019 | 8/20/2019 | P | PART |
Brian Scoles
|
|
|
undergound gas line Phone #: ###-#### Inspection requested via web by Joseph Profitt- 20lb gas pass- need minimum 12" below grade on underground gas piping piping near mobile home not deep enough
|
Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt- poly pipe needs anodised riser both ends and approved manufacture flex connector on outside of mobile home- went over onsite with installer and talked to Joeseph by phone
|
Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 | P | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
Issue PAID IN FULL permit | | | 8/14/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/14/2019 | | DONE |
|
|
|
This permit was created on the web by Joseph Profitt
|