Final | 10/25/2019 | 10/25/2019 | 10/25/2019 | P | PASS |
Brian Scoles
|
|
|
Suite # 103, Lock box code 3266 Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- final ok- per phone call with Tyson engineer transfer for break room not needed
|
Rough-in | 9/4/2019 | 9/4/2019 | 9/4/2019 | A | PASS |
Brian Scoles
|
|
|
Code is 3266, should be unlocked. Suite 103 Inspection requested via web by Floyd Floyd Peek- R/I ok- engineer approved duct routing per stamped document on window- need misc insulation completed-
|
Rough-in | 8/29/2019 | 8/29/2019 | 8/29/2019 | P | FAIL |
Brian Scoles
|
|
|
Inspection requested via web by Floyd Floyd Peek- ducting not installed per print- need to get engineer approval for hows installed now- missing 4 supply registers and 1 transfer- sizing on some supplies are under sized-
|
Rough-in | 8/29/2019 | 8/29/2019 | 8/29/2019 | A | CANC |
Brian Scoles
|
|
|
I will go un-lock this morning >> Inspection requested via web by Floyd Floyd Peek Inspection cancelled from web by: Floyd Floyd Peek
|
Rough-in | 8/28/2019 | 8/28/2019 | 8/28/2019 | P | FAIL |
Brian Scoles
|
|
|
Inspection requested via web by Floyd Floyd Peek- no access locked up
|
Rough-in | 8/26/2019 | 8/26/2019 | 8/26/2019 | A | PART |
Brian Scoles
|
|
|
Need partial for dryer vent Inspection requested via web by Floyd Floyd Peek- dryer duct only ok to cover- please include which suite # it is on next inspection
|
Rough-in | 8/23/2019 | 8/23/2019 | 8/23/2019 | A | FAIL |
Brian Scoles
|
|
|
Need partial Rough-in for dryer vent on back wall. Need ok to cover. Inspection requested via web by Floyd Floyd Peek- dryer vent ran in 3.5" wall- wall needs firred out dryer has to maintain 4" round- duct outside of framing
|
Issue PAID IN FULL permit | | | 8/23/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/23/2019 | | DONE |
|
|
|
This permit was created on the web by Floyd Floyd Peek
|