Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberMEC19-04091
StatusFinaled
Name INTEGRITY HEATING & AIR LLC
Site Address 11467 W ALDERSHOT DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Install new complete HVAC in new construction residential home with gas piping.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/7/20201/8/20201/8/2020APASS
DetailsBrian Scoles
Garage Code: 1234
If this does not work please contact Sam with Simplicity Homes ###-#### Phone #: ###-#### Inspection requested via web by Terek Worley
Final1/6/20201/6/20201/6/2020PFAIL
DetailsJack Reynolds
garage code 1234 Phone #: ###-#### Inspection requested via web by Terek Worley
- need locking caps installed on A/C
- range vent termination is blocked need clearances
Rough-in10/17/201910/18/201910/18/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley- R/I ok- will need clearance around exterior range hood penetration partially below grade at final
Pressure Test10/15/201910/15/201910/15/2019PCANC
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley- already passed
Rough-in10/15/201910/15/201910/15/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley
1- missing transfer registers in bedroom 2 and 4
2- need to insulate outside air filter box and r/a can to r-6
3- need to finish range duct in crawl to outside on R/I inspection

left notice front window
Fees Due Hold10/11/2019 10/15/2019 DONE
Details
Pressure Test10/9/201910/10/201910/10/2019APASS
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Terek Worley
- already passed -
Rough-in10/9/201910/10/201910/10/2019AFAIL
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Terek Worley
- corrections not made, reinspection fee issued -
Rough-in10/7/201910/8/201910/8/2019AFAIL
DetailsBrian Scoles
Please contact Project Manager Sam before inspection so that he can ensure a ladder is available (208)-###-#### Phone #: ###-#### Inspection requested via web by Terek Worley
1- missing transfer grills bedroom 2 and 4
2- range duct needs completed
3- need to insulate outside air filter box to minimum R-6

left notice front window
Pressure Test10/7/201910/8/201910/8/2019ACANC
DetailsBrian Scoles
Please contact Project Manager Sam before inspection so that he can ensure a ladder is available (208)-###-#### Phone #: ###-#### Inspection requested via web by Terek Worley- already passed gas test
Rough-in9/26/20199/26/20199/26/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley
1- missing transfer register in bedroom 2 and 4
2- 2nd drain needs ran
3- need range ducting installed ??
4- need nail plate bedroom 3 at ceiling on 3/4" pvc drain
5- b vent for water heater at roof needs 1" clearance to combustibles
6- need to insulate register can R/A where 6" outside air duct was removed
7- need to insulate outside air filter box in attic

left correction n otice front window
Pressure Test9/26/20199/26/20199/26/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass- tagged meter location
Pressure Test9/24/20199/25/20199/24/2019ACANC
DetailsBrian Scoles
Phone #: ###-#### >> Inspection requested via web by Terek Worley Inspection cancelled from web by: Terek Worley
Rough-in9/24/20199/25/20199/24/2019ACANC
DetailsBrian Scoles
Phone #: ###-#### >> Inspection requested via web by Terek Worley Inspection cancelled from web by: Terek Worley
Issue PAID IN FULL permit  9/13/2019 DONE
Payment received via Govolutions
Application received  9/13/2019 DONE
This permit was created on the web by Terek Worley