Final | 2/3/2020 | 2/4/2020 | 2/4/2020 | A | PASS |
Ben Livingston
|
|
|
AC: 1905 Phone #: ###-#### Inspection requested via web by Gary Reeves
|
Final | 1/28/2020 | 1/28/2020 | 1/28/2020 | P | CANC |
Jack Reynolds
|
|
|
AC:1905 Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
Final | 1/27/2020 | 1/27/2020 | 1/27/2020 | P | FAIL |
Jack Reynolds
|
|
|
AC: 1905 Phone #: ###-#### Inspection requested via web by Gary Reeves - A/C's need locking caps installed on service ports - crawl ventialtion vent pipe needs sealed in garage - need two seperate duct blasts performed on each hvac system - high pressure gas valve at regulator needs adjusted so it can open 100%
|
Rough-in | 10/14/2019 | 10/14/2019 | 10/14/2019 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - R/I ok
|
Rough-in | 10/11/2019 | 10/11/2019 | 10/11/2019 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - Man J onsite was for a house in meridian
|
Rough-in | 10/3/2019 | 10/4/2019 | 10/4/2019 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - need stamped Man J onsite
|
Pressure Test | 10/3/2019 | 10/4/2019 | 10/4/2019 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - water heater 5lb flue pressure test ok
|
Rough-in | 10/2/2019 | 10/3/2019 | 10/3/2019 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - need stamped man J onsite - return air for both furnaces not per prints - fresh air needs to tap off furnace return plenum not return can - water heater 5lb flue fail
|
Pressure Test | 10/2/2019 | 10/3/2019 | 10/3/2019 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - 5lb flue for furnace ok - 20lb and 60lb gas pressure test ok - tagged meter location - water heater 5lb flue test fail under 5lb
|
Issue PAID IN FULL permit | | | 9/13/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 9/13/2019 | | DONE |
|
|
|
This permit was created on the web by Gary Reeves
|