Final | 3/20/2020 | 3/23/2020 | 3/23/2020 | A | PASS |
Brian Scoles
|
|
|
Phone number is for Cindy with Mr. Fix-It; She asked for a call if able to when on the way or at property Phone #: ###-#### Inspection requested via web by Loren Bailey- final ok
|
Rough-in | 11/7/2019 | 11/8/2019 | 11/8/2019 | A | PASS |
Brian Scoles
|
|
|
Inspection requested via web by Loren Bailey- R/I ok
|
Pressure Test | 11/8/2019 | 11/8/2019 | 11/8/2019 | A | PASS |
Brian Scoles
|
|
|
Inspection requested via web by Loren Bailey- 20lb gas pass- tagged meter location- 5lb flue pass
|
Rough-in | 11/7/2019 | 11/7/2019 | 11/7/2019 | P | PART |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Loren Bailey- R/I will pass when pressure test passes on flue and gas
|
Pressure Test | 11/7/2019 | 11/7/2019 | 11/7/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Loren Bailey- gas gauge at zero- flue test gauge at zero gauge need to be maximum 15psi not 30psi- need to replace threaded protector at meter location to approved fitting before gas turned on
|
Rough-in | 10/23/2019 | 10/24/2019 | 10/24/2019 | A | NR |
Brian Scoles
|
|
|
11am if at all possible Phone #: ###-#### Inspection requested via web by Kim Evans- still need to figure whats going on with 3 bath fans that need vented and dryer ducting0 no cover til installed- talked with installer and GC onsite
|
Pressure Test | 10/23/2019 | 10/24/2019 | 10/24/2019 | A | FAIL |
Brian Scoles
|
|
|
11 am if at all possible Phone #: ###-#### Inspection requested via web by Kim Evans- flue not holding pressure- gas gauge doesnt work
|
Rough-in | 10/22/2019 | 10/23/2019 | 10/23/2019 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans 1- need to seal all spotwelds on r/a and supply boots 2- no gas on test 3- dryer duct needs ran on r/i 4- exhaust fan ducting not ran and need to add 3 to permit and pay fee 5- will need fue test witnessed since intake and exhaust were rerouted 6- transfers for bedrooms and laundry room??
left notice front window
|
Meeting | | | 10/23/2019 | | DONE |
|
|
|
Josh with Elite Systems called to inform us that the permit is pulled wrong and no dryer vent is being done.
|
Issue PAID IN FULL permit | | | 10/22/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/22/2019 | | DONE |
|
|
|
This permit was created on the web by Kim Evans
|