Final | 3/4/2020 | 3/5/2020 | 3/5/2020 | A | PASS |
Jack Reynolds
|
|
|
back door is unlocked Phone #: ###-#### Inspection requested via web by Michael Stimpson - final ok
|
Final | 2/28/2020 | 3/2/2020 | 3/2/2020 | A | FAIL |
Jack Reynolds
|
|
|
Back door is unlocked Phone #: ###-#### Inspection requested via web by Michael Stimpson - A/C needs locking caps installed on service ports - line set penetration needs sealed - gas line at meter needs two supports - range vent needs to be smooth walled pipe
|
Rough-in | 12/7/2019 | 12/9/2019 | 12/9/2019 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Stimpson - R/I ok
|
Rough-in | 12/6/2019 | 12/6/2019 | 12/6/2019 | P | FAIL |
Jack Reynolds
|
|
|
-range vent seal ok - flue needs 1" clearances through roof - when draft stop is in place at attic need to see clearances/ insulation shield
|
Rough-in | 12/5/2019 | 12/6/2019 | 12/6/2019 | A | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Stimpson - need access to see new flue pipe in attic - range vent needs sealed
|
Telephone call | | | 12/6/2019 | | DONE |
|
|
|
Micheal with Snowflake called to add a range hood to the permit.
|
Pressure Test | 10/24/2019 | 10/25/2019 | 10/25/2019 | A | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Michael Stimpson - 20lb gas pressure test ok - need to add a few temp supports to gas line until floor joists are installed and one more at meter
|
Issue PAID IN FULL permit | | | 10/24/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/24/2019 | | DONE |
|
|
|
This permit was created on the web by Michael Stimpson
|