Final | 1/20/2020 | 1/21/2020 | 1/21/2020 | A | PASS |
Chad Schwendiman
|
|
|
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE
|
Rough-in | 11/19/2019 | 11/19/2019 | 11/19/2019 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE - R/I ok
|
Pressure Test | 11/19/2019 | 11/19/2019 | 11/19/2019 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE - 5lb flue pressure test ok - 20lb gas pressure test ok -tagged meter location
|
Rough-in | 11/17/2019 | 11/18/2019 | 11/18/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 1- gas gauge at zero psi 2- flue test below 5psi and needs max 15lb gauge 3- all exposed insulation on R/A and supply mains in attic needs vapor barrier installed above blow in insulation line 4- need to insulate bare metal on supply duct tap above garage and tape insulation
left correction notice front window
|
Pressure Test | 11/17/2019 | 11/18/2019 | 11/18/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- gas gauge at zero- flue test below 5psi and needs max 15psi gauge not 30
|
Issue PAID IN FULL permit | | | 11/17/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/17/2019 | | DONE |
|
|
|
This permit was created on the web by JOSE DUARTE
|