Permit Information
Permit NumberMEC19-05296
StatusFinaled
Name IDAHO GEOTHERMAL
Site Address 3909 W NORMANDIE DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Retrofit: New furnace, coil, A/C some ductwork replacement.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/25/20206/26/20206/26/2020PPASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Bryan Palmer
- final ok
Pressure Test6/25/20206/26/20206/26/2020PPASS
DetailsJack Reynolds
Gas pressure test - gas fireplace Phone #: ###-#### Inspection requested via web by Bryan Palmer
- 20lb gas test ok
Final6/24/20206/25/20206/25/2020PPART
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Bryan Palmer
- add fireplace and gas pressure test to permit
- cover on fireplace insert will need to be removed for inspection. And new gas line will need to be pressure tested.
Final6/22/20206/23/20206/23/2020AFAIL
DetailsJack Reynolds
Lockbox located on shed on east side of house - 0314 Phone #: ###-#### Inspection requested via web by Bryan Palmer
- A/C locking caps
- need to add dryer and bath exhaust to permit
- need duct blast and air balance onsite
Rough-in11/26/201911/27/201911/27/2019APASS
DetailsBrian Scoles
Please call Mike 1 / 2 hr. before arrival - ###-#### Phone #: ###-#### Inspection requested via web by Bryan Palmer- R/I ok- still need to add dryer duct and bath fan to permit and pay fees by final- utility rm and family room will be installed with cabinet guys for routing- will need duct blast and air balance by final
Rough-in11/22/201911/22/201911/22/2019PNR
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Bryan Palmer
1- need approved man j onsite
2- range duct will install at final
3- family rm and utility rm will have supply ducting completed at final has to work with cabinet guys
4- condensate in crawl has pvc installed 5 feet into crawl to post and beam poly line from pump to that location wasnt any way to acheive grade
5- man j will be updated
6- need to add dryer duct and exhaust fan to permit
Pressure Test11/22/201911/22/201911/22/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Bryan Palmer- 5lb flue pass
Rough-in11/21/201911/22/201911/22/2019AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Bryan Palmer
1- need to resubmit man j all equipment does not match approved man j
2- who installed exhaust fan? need to add to permit
3- range duct ?
4- family room and utility room need supply registers install per man J
5- flue needs tested
6- condensate pump is in alarm and need to run 3/4 inch pvc from furnace to outside and run minimal poly tube from furnace to outside with grade
7- bedroom 3 shows 4x10 boot not 2 x 14
secondary drain and primary off coil need completed

left notice onsite
Issue PAID IN FULL permit  11/21/2019 DONE
Payment received via Govolutions
Application received  11/21/2019 DONE
This permit was created on the web by Bryan Palmer