Final | 12/13/2019 | 12/16/2019 | 12/16/2019 | P | PASS |
Brian Scoles
|
|
|
El-Ada #A-10755; Sarah Bowman Phone #: ###-#### Inspection requested via web by Loren Bailey- furnace a/c coil co locking caps ok
|
Final | 12/10/2019 | 12/10/2019 | 12/10/2019 | P | FAIL |
Brian Scoles
|
|
|
El-Ada #A-10755 Sarah Bowman Phone #: ###-#### Inspection requested via web by Loren Bailey- need locking caps on a/c service ports- flue can not go from single wall to b vent and then back to single wall- use approved double wall reducer and route all in b vent and verify b vent outside is not corroded and still intact mayy need replaced- need to verify clearances to combustion per manufacture installation instructions on furnace since washer machine is in front of it-
|
Issue PAID IN FULL permit | | | 11/25/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/25/2019 | | DONE |
|
|
|
This permit was created on the web by Loren Bailey
|