Final | 2/3/2020 | 2/3/2020 | 2/3/2020 | P | PASS |
Jack Reynolds
|
|
|
Re inspection. Items were fixed. Phone #: ###-#### Inspection requested via web by Nicolas Barajas - final ok
|
Final | 1/31/2020 | 1/31/2020 | 1/31/2020 | P | FAIL |
Jack Reynolds
|
|
|
Door Should be open, if is not, there is a key under the seat of the dump truck that is park outside. Manual J and, duct blast and balance should be by the furnace. Phone #: ###-#### Inspection requested via web by Nicolas Barajas - high and low combustion air grilles mech closet - locking caps for A/C - landscraping rocks are covering line set outside
|
Rough-in | 12/19/2019 | 12/19/2019 | 12/19/2019 | P | PASS |
Jack Reynolds
|
|
|
Re inspection. We corrected the items on the red tag. New manual J on site Phone #: ###-#### Inspection requested via web by Nicolas Barajas - R/I ok
|
Rough-in | 12/18/2019 | 12/18/2019 | 12/18/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Nicolas Barajas- need to resubmit man j- equipment oriented different than man j- R/A ducting for second floor different than whats installed- shows ducted R/A in master has transfer- missing 14" round R/A second floor now is side wall off furnace or install per approved man j 2-need to seal dryer duct to termination box in wall 3-exhaust fan second floor needs finished 4- crawl needs completed on R/I inspection
left notice on window
|
Pressure Test | 12/18/2019 | 12/18/2019 | 12/18/2019 | P | PASS |
Brian Scoles
|
|
|
Gas to Furnace, WH and range Phone #: ###-#### Inspection requested via web by Nicolas Barajas- 20lb gas pass tagged meter location- 5lb flue pass
|
Issue PAID IN FULL permit | | | 12/6/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/6/2019 | | DONE |
|
|
|
This permit was created on the web by Nicolas Barajas
|