Pressure Test | 12/20/2019 | 12/20/2019 | 12/20/2019 | P | PASS |
Brian Scoles
|
|
|
Please call homeowner 30 minutes in advance for access at ###-#### and call Eddie with questions at ###-####. Phone #: ###-#### Inspection requested via web by Rhonda Marcum- 20lb gas pass co ok
|
Final | 12/20/2019 | 12/20/2019 | 12/20/2019 | P | PASS |
Brian Scoles
|
|
|
Please call homeowner 30 minutes in advance for access at ###-#### and call Eddie with questions at ###-####. Phone #: ###-#### Inspection requested via web by Rhonda Marcum
|
Pressure Test | 12/19/2019 | 12/19/2019 | 12/19/2019 | P | FAIL |
Brian Scoles
|
|
|
Please call homeowner 30 minutes in advance for access at ###-#### and call Eddie with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- gauge below 20psi
|
Pressure Test | 12/16/2019 | 12/16/2019 | 12/16/2019 | P | FAIL |
Brian Scoles
|
|
|
Please call homeowner 30 minutes in advance for access at ###-#### and call Eddie with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- gauge at zero- need to add second shutoff valve in water heater closet after drip leg and leave drip leg open- at no time can air be on onside of valve and gas on other has to have 2 shut off valves with open tee between them- will need co detectors installed also near bedrooms- make sure gauge zeros out too
|
Issue PAID IN FULL permit | | | 12/16/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/13/2019 | | DONE |
|
|
|
This permit was created on the web by Rhonda Marcum
|