Final | 4/23/2020 | 4/23/2020 | 4/23/2020 | P | PASS |
Jack Reynolds
|
|
|
2583 is garage code Inspection requested via web by Loren Bailey - final ok
|
Final | 4/22/2020 | 4/22/2020 | 4/22/2020 | P | FAIL |
Jack Reynolds
|
|
|
Garage code 2583 Phone #: ###-#### Inspection requested via web by Loren Bailey - line set insulation at outdoor unit needs repaired and UV protected
|
Pressure Test | 2/5/2020 | 2/6/2020 | 2/6/2020 | A | PASS |
Brian Scoles
|
|
|
Pressure test for flue Phone #: ###-#### Inspection requested via web by Loren Bailey- 5lb flue pass
|
Rough-in | 2/3/2020 | 2/4/2020 | 2/4/2020 | A | PASS |
Jack Reynolds
|
|
|
Inspection requested via web by Loren Bailey - flue test failed gauge under 5lb will need to see 5lb witness at final or reschedule a 5lb flue test before final - R/I ok
|
Fees Due Hold | 1/31/2020 | 1/31/2020 | 2/3/2020 | | DONE |
|
|
|
|
Rough-in | 1/30/2020 | 1/31/2020 | 1/31/2020 | A | FAIL |
Brian Scoles
|
|
|
Inspection requested via web by Loren Bailey- corrections not made 1- need to fix kink in lineset at crawl entrance and repair all arma flex in crawl exposed copper showing 2- need 1" clearance to sheet rock on w/h flue 3- range duct needs seal at roof and roof jack is off roof looking from outside 4- need to see flue test for witness
see notice front entry window
reinspection fee issued
|
Pressure Test | 1/31/2020 | 1/31/2020 | 1/31/2020 | A | FAIL |
Brian Scoles
|
|
|
Inspection requested via web by Loren Bailey- 20lb gas pass tagged meter location- need to see flue test per earlier notes
|
Rough-in | 1/30/2020 | 1/30/2020 | 1/30/2020 | P | FAIL |
Brian Scoles
|
|
|
Inspection requested via web by Loren Bailey- not all corrections are made- see notice front entry window
|
Pressure Test | 1/30/2020 | 1/30/2020 | 1/30/2020 | P | FAIL |
Brian Scoles
|
|
|
Inspection requested via web by Loren Bailey- gauge wont zero out on gas line
|
Rough-in | 1/29/2020 | 1/29/2020 | 1/29/2020 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Loren Bailey - line set in crawl needs arma flex repaired and copper line fixed from being over bend - 20 lb fail gauge under 20lb - need to see a 5lb flue test - b vent needs 1' clearances high and low - range vent needs sealed near roof line
|
Pressure Test | 1/29/2020 | 1/29/2020 | 1/29/2020 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Loren Bailey - 20lb gas pressure test fail gauge under 20lb - need to see 5lb flue pressure test
|
Issue PAID IN FULL permit | | | 1/7/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/7/2020 | | DONE |
|
|
|
This permit was created on the web by Loren Bailey
|