DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Rough-in2/28/20202/28/20202/28/2020PPASS
DetailsBrian Scoles
Hazen Phone #: ###-####- r/i ok- ok to cover exterior chase- need to seal storm collar by final
Rough-in2/14/20202/18/20202/18/2020PFAIL
DetailsBrian Scoles
Sheldon Phone #: ###-####- need to remove siding around flue to check clearances to pipe- will need to insulate chase to R-8 per codes thats referenced
Rough-in2/3/20202/3/20202/3/2020PFAIL
DetailsBen Livingston
ROUGH IN ON EXTERIOR PIPE Phone #: ###-#### Inspection requested via web by Sheldon Lebow
- building permit and inspected prior to cover -
- still need BLD permit before MEC reinspection -
Rough-in1/17/20201/21/20201/21/2020APART
DetailsBrian Scoles
PLEASE CALL SHELDON 1 HR BEFORE SO HE CAN MEET YOU OUT THERE. ###-#### Phone #: ###-#### Inspection requested via web by Sheldon Lebow- fireplace R/I in living room only ok for cover- insulation shield verified in attic- need framing completed around b vent above roof and call in for inspection once framed and this will require a building permit and inspected prior to cover
Rough-in1/17/20201/17/20201/17/2020PFAIL
DetailsBrian Scoles
GARAGE CODE IS 1129. PLEASE KNOCK ON THE DOOR TO SEE IF HOMEOWNERS ARE HOME, IF NOT USE GARAGE CODE Phone #: ###-#### Inspection requested via web by Sheldon Lebow
1- need to secure csst gas piping behind fireplace laying against it
2- contractor needs to provide ladder to access attic to check clearances and insulation shield and roof to check clearances on b vent up exterior wall and may need supported cant verify from ground
3- need framing completed around exterior b vent per 2428.2.9 and this will require a building permit and have inspected

draft stop seal and metal ok above fireplace
Rough-in1/14/20201/15/20201/15/2020PFAIL
DetailsBrian Scoles
GARAGE CODE IS 1129. PLEASE KNOCK ON THE DOOR TO SEE IF HOMEOWNERS ARE HOME, IF NOT USE GARAGE CODE. Phone #: ###-#### Inspection requested via web by Sheldon Lebow
1- need gas piping stubbed into fireplace
2- metal firestop at ceiling in fireplace chase needs to cover hole completely and firecaulked around b vent
3- need ladder provided by contractor to access piping in attic to verify insulation shield
4- need b vent installation instructions for b vent onsite - piping ran exposed on outside of house above garage roof line needs to to meet G2428.2.9 of IRC or manufactures installation instruction stating b vent can be ran exposed
Rough-in1/10/20201/13/20201/13/2020ANH
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Sheldon Lebow- no one home- no access