Final | 4/30/2020 | 4/30/2020 | 4/30/2020 | A | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - final ok
|
Final | 4/29/2020 | 4/29/2020 | 4/29/2020 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - need duct blast onsite - high and low combustion air opening for water heater
|
Final | 4/27/2020 | 4/27/2020 | 4/27/2020 | P | NR |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart
|
Rough-in | 2/5/2020 | 2/6/2020 | 2/6/2020 | P | PASS |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart
|
Rough-in | 2/4/2020 | 2/5/2020 | 2/5/2020 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - duct insulation in crawl ok - changes to Man J need to be submitted to city for approval - duct seal needs to be finished
|
Rough-in | 1/31/2020 | 1/31/2020 | 1/31/2020 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - Man J doesn't match equipment or ducting upstairs - all duct work needs sealed - duct work in crawl needs insulated
|
Rough-in | 1/30/2020 | 1/31/2020 | 1/31/2020 | A | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - There still is no approved manual J onsite
|
Pressure Test | 1/30/2020 | 1/31/2020 | 1/31/2020 | A | PASS |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - 5lb flue
|
Pressure Test | 1/29/2020 | 1/30/2020 | 1/30/2020 | A | PART |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - 5lb flue fail. 60lb gas pass
|
Rough-in | 1/29/2020 | 1/30/2020 | 1/30/2020 | A | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - Need approved manual J onsite, Missing insulation shield on b-vent in attic, 5lb flue pressure fail
|
Issue PAID IN FULL permit | | | 1/29/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/29/2020 | | DONE |
|
|
|
This permit was created on the web by Randy Hart
|