Final | 2/5/2020 | 2/7/2020 | 2/7/2020 | P | PASS |
Jack Reynolds
|
|
|
Please call prior to arrival Phone #: ###-#### Inspection requested via web by Jamee Shoecraft - fireplace final ok
|
Final | 2/3/2020 | 2/4/2020 | 2/4/2020 | P | CANC |
Jack Reynolds
|
|
|
PLEASE CALL RANDY PRIOR TO ARRIVAL Phone #: ###-#### Inspection requested via web by Jamee Shoecraft - not ready for final
|
Rough-in | 2/4/2020 | 2/4/2020 | 2/4/2020 | P | PASS |
Jack Reynolds
|
|
|
PLEASE CALL RANDY PRIOR TO ARRIVAL Phone #: ###-#### Inspection requested via web by Jamee Shoecraft - R/I and clearances ok - need to see gas line sleeved / CSST supported in crawl and tied in by final
|
Pressure Test | 1/30/2020 | 1/31/2020 | 1/31/2020 | P | FAIL |
Jack Reynolds
|
|
|
Gas pressure test and final fireplace inspection. Please call Randy prior to arrival Phone #: ###-#### Inspection requested via web by Jamee Shoecraft - CSST needs sleeved at fireplace - CSST needs support in crawl space - fireplace needs clearances to combustibles on top and sides - 20lb gas ok not sure where connection will be but need to see tie in at final
|
Issue PAID IN FULL permit | | | 1/30/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/30/2020 | | DONE |
|
|
|
This permit was created on the web by Jamee Shoecraft
|