Final | 5/12/2020 | 5/12/2020 | 5/12/2020 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Sarah Small- final ok
|
Card not on site to sign | 5/12/2020 | 5/12/2020 | 5/12/2020 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Sarah Small- card not onsite ti sign
|
Final | 5/11/2020 | 5/12/2020 | 5/12/2020 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Sarah Small 1- mini split condenser needs locking caps on service ports 2- condenser needs secured to poly 3" supports 3- need to remove foil tape from b vent near unit heater and install trim ring around b vent and firecaulk 4- need to fire caulk gas line and (4) allthread penetrations in ceiling of garage
left notice front room window
|
Final | 4/14/2020 | 4/15/2020 | 4/14/2020 | A | CANC |
Brian Scoles
|
|
|
Call Don if any questions @ ###-#### Phone #: ###-#### >> Inspection requested via web by Sarah Small Inspection cancelled from web by: Sarah Small
|
Final | 2/28/2020 | 2/28/2020 | 2/28/2020 | P | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Sarah Small- should have been R/I inspection
|
Rough-in | 2/28/2020 | 2/28/2020 | 2/28/2020 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Sarah Small- R/I ok- 20lb gas pass sectioned tested
|
Final | 2/26/2020 | 2/26/2020 | 2/26/2020 | P | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Sarah Small- should have been R/I inspection
|
Rough-in | 2/26/2020 | 2/26/2020 | 2/26/2020 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Sarah Small 1- poly vinyl tubing not approved material needs ran in 3/4 inch pvc close to head on center block wall and graded 1/4inch per foot in attic to exterior 2- b vent needs 1" clearance to combustibles at roof and insulation shield installed 3- need open tee between 2 shutoff valves on gas line for pressure test/ retest gas line when fixed
correction notice post in window
|
Issue PAID IN FULL permit | | | 2/10/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/10/2020 | | DONE |
|
|
|
This permit was created on the web by Sarah Small
|
First Notice | 5/12/2020 | 5/12/2020 | | | |
Brian Scoles
|
|
|
|