Final | 7/30/2020 | 7/30/2020 | 7/30/2020 | P | PASS |
Brian Scoles
|
|
|
Please use code 4888 for entry Phone #: ###-#### Inspection requested via web by Sarah Small- final ok
|
Final | 7/27/2020 | 7/29/2020 | 7/29/2020 | A | FAIL |
Chad Schwendiman
|
|
|
Use Code 4888 Phone #: ###-#### Inspection requested via web by Sarah Small - Duct blast failed. Need to pass duct blast and have an air balance report on site
|
Final | 7/24/2020 | 7/27/2020 | 7/27/2020 | A | FAIL |
Brian Scoles
|
|
|
Please use lock box code 4888 Phone #: ###-#### Inspection requested via web by Sarah Small 1- need duct blast and air balance completed 2- locking caps on a.c service ports 3- seal exterior gas line penetration at meter location 4- need to fire caulk all penetrations in garage IE linset and drains, b vent and pvc flue and where low voltage goes into crawl
|
Rough-in | 3/12/2020 | 3/13/2020 | 3/13/2020 | A | PASS |
Brian Scoles
|
|
|
Access code should be 4888 - it will be in a key box - call Eric @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire- R/I ok- need to duct toe kick in 1st floor bathroom and insulate supply main in crawl
|
Pressure Test | 3/12/2020 | 3/13/2020 | 3/13/2020 | A | PASS |
Brian Scoles
|
|
|
Access code should be 4888 - it will be in a key box - call Eric @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire- 20lb gaspass- 5lb flue pass
|
Rough-in | 3/5/2020 | 3/6/2020 | 3/6/2020 | A | FAIL |
Brian Scoles
|
|
|
You will need to access the property through a lock box the code is 4888 Phone #: ###-#### Inspection requested via web by Sarah Small 1- flue test failed and gauge needs to max 15 lb gauge 2- missing transfer grill 1st floor bedroom 3 3- crawl needs completed on R/I inspection 4- toe kicks need ducted out to register can not communicate with cabinet 5- 2 bath fans first floor needs metal to plastic sealed at fan locations
left notice front window
|
Pressure Test | 3/5/2020 | 3/6/2020 | 3/6/2020 | A | FAIL |
Brian Scoles
|
|
|
we need a flue inspection test for a high efficiency furnace install also gas pressure test on gas line You will access the property with lock box the code is 4888 Phone #: ###-#### Inspection requested via web by Sarah Small- 20lb gas pass tagged meter location- 5lb flue at zero and needs tested on max 15lb gauge
|
Issue PAID IN FULL permit | | | 3/2/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/2/2020 | | DONE |
|
|
|
This permit was created on the web by Angie Maguire
|