Pressure Test | 5/18/2020 | 5/18/2020 | 5/18/2020 | P | PASS |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN -20lb ,5lb
|
Rough-in | 5/18/2020 | 5/18/2020 | 5/18/2020 | P | PASS |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
|
Pressure Test | 5/15/2020 | 5/18/2020 | 5/18/2020 | A | FAIL |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - need 20lb on a 30lb gauge, or 60lb on a 100lb gauge - incorrect gauge for test
|
Pressure Test | 5/14/2020 | 5/15/2020 | 5/15/2020 | A | NR |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - still working on gas piping - 5lb flue okay
|
Pressure Test | 5/14/2020 | 5/14/2020 | 5/14/2020 | P | NR |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN -still working
|
Rough-in | 5/14/2020 | 5/14/2020 | 5/14/2020 | P | PART |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - rough-in will pass when pressure test passes
|
Issue PAID IN FULL permit | | | 5/14/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 5/14/2020 | | DONE |
|
|
|
This permit was created on the web by GREGORY ANDERSEN
|