Alteration or Repair: Install Furnace, and A/C - Ducting and Vents
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/2/20207/6/20207/6/2020APASS
DetailsJack Reynolds
Inspection requested via web by Sarah Small
- R/I ok
Fees Due Hold7/2/2020 7/2/2020 DONE
Details
Final7/1/20207/2/20207/2/2020AFAIL
DetailsJack Reynolds
Please use access code 4888 Phone #: ###-#### Inspection requested via web by Sarah Small
- fees need paid
Rough-in6/30/20207/1/20207/1/2020AFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Sarah Small
- corrections still need made
- reinspection fee applied
Rough-in6/16/20206/18/20206/18/2020AFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Sarah Small
- section of b vent still needs replaced has screw through inner liner
- add all exhaust fans to permit details
Pressure Test6/16/20206/18/20206/18/2020APASS
DetailsJack Reynolds
Gas Pressure Test Phone #: ###-#### Inspection requested via web by Sarah Small
- 5lb flue test ok
- 20lb gas test ok
- tagged meter location
Rough-in6/15/20206/16/20206/16/2020AFAIL
DetailsJack Reynolds
Access Code: 4888 Phone #: ###-#### Inspection requested via web by Sarah Small
- b vent needs replaced at roof line and needs 1" clearance to flex
- all bedrooms need transfer air openings
- toe kick in kitchen needs ducted out of cabinet
- add all exhaust fans to permit details
Pressure Test6/15/20206/16/20206/16/2020AFAIL
DetailsJack Reynolds
Gas Pressure Test - Access Code: 4888 Phone #: ###-#### Inspection requested via web by Sarah Small
- gas line needs either disconnected from meter or a tell tale valve installed
- new pvc flue for furnace needs tested