Permit Information
Permit NumberMEC20-02526
StatusIssued
Name ALLEY HEATING & COOLING
Site Address 8159 W TUDOR LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Complete HVAC Installation: MINI SPLIT SYSTEMS, 4 HEADS INDOOR, FIREPLACE, KITCHEN VENT, DRYER VENT, DUCTWORK FOR MINI SPLIT, GAS PIPING, BATH VENT,

Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Rough-in7/15/20207/15/20207/15/2020PPASS
DetailsBrian Scoles
Correction have been made Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
Rough-in7/10/20207/10/20207/10/2020PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- access platfornma and access needs installed 24 inch wide and 30x30 in front of mini split- went over with Andrey onsite
Fees Due Hold7/7/20207/7/20207/7/2020 DONE
Details
per Brian verify reinspection fee paid before scheduling another inspection
Rough-in7/6/20207/7/20207/7/2020AFAIL
DetailsBrian Scoles
CORRECTIONS COMPLETED AS REQUESTED READY FOR REINSPECTION Phone #: ###-#### Inspection requested via web by Oleg Chervak- items 1 3 7 and 8 still need corrections addressed- reinspection fee issued
Rough-in6/29/20206/30/20206/30/2020PFAIL
DetailsBrian Scoles
nail plate installed manual j on site please reinspect Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- need access platform in attic to mini split with 30" clearance and unobstructed
2- dryer duct notch needs enlarged
3- will need condensate ran for condenser on balcony
4- range duct completed below framing
5- fireplace needs uncovered and instructions available
6- condensate needs ran for balcony condenser
7- transfer laundry and bathroom
8- remove undo stress on pvc drain 1st floor north bedroom wall

left notice
Rough-in6/26/20206/26/20206/26/2020PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need city approved man j onsite- fireplace needs would covering it removed- missing nail plate 1st floor on lineset-
Pressure Test6/26/20206/26/20206/26/2020PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
Conference6/23/20206/23/20206/23/2020PDONE
DetailsBrian Scoles
PLEASE CONTACT ANDREY AND WALKTHOUGH THIS PROJECT WITH HIM. WE WANT TO BE SURE THAT WE ARE CODE COMPLIANT, THANK YOU Phone #: ###-#### Inspection requested via web by Oleg Chervak- discussed pvc drains- condenser middle units need pvc drain/pan installed under condenser and freeze protection provided- 1st floor middle units need exhaust fan minimum 3 feet from property line- went over with Alex onsite
Issue PAID IN FULL permit  6/22/2020 DONE
Payment received via Govolutions
Application received  6/22/2020 DONE
This permit was created on the web by Oleg Chervak