Rough-in | 7/28/2020 | 7/28/2020 | 7/28/2020 | P | PASS |
Jack Reynolds
|
|
|
Access in back of house.
Wood stove vent will be removed and not used. Phone #: ###-#### Inspection requested via web by Tony Fogg - R/I ok
|
Rough-in | 7/24/2020 | 7/24/2020 | 7/24/2020 | P | FAIL |
Jack Reynolds
|
|
|
This is an unoccupied remodel. If no one is on site you can access the house from the back yard door. Phone #: ###-#### Inspection requested via web by Tony Fogg - CSST gas line needs to be free floating inside wall. Take one support out at top of wall - dryer vent needs to be installed in a 2x6 wall - need information on whats happening with the old wood stove and vent - water heater b vent needs replaced screws penetrated inner liner
|
Pressure Test | 7/24/2020 | 7/24/2020 | 7/24/2020 | P | PASS |
Jack Reynolds
|
|
|
This is an unoccupied remodel. If no one is on site you can access the house from the back yard door. Phone #: ###-#### Inspection requested via web by Tony Fogg - 20lb gas test ok for water heater
|
Issue PAID IN FULL permit | | | 7/22/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/22/2020 | | DONE |
|
|
|
This permit was created on the web by Tony Fogg
|