Permit Information
Permit NumberMIS09-00111
StatusExpired
Name KATHERINE PIECHURA
Site Address 2025 S DENVER AVE
Project Name 
Customer Number 
ePlanReview 
Description
substandard renters complaint: insurance company said they need 20 amp circuit breakers, no stove, glass in 2 windows broken, bathroom floor water damage from bathtub, bathroom ceiling caving in, front door doesn't close properly, toilet needs wax ring, some of the heater vents don't have any ducting they go straight to the outside.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
MIS-Aging Inspection12/21/200912/21/200912/22/2009 DONE
DetailsJim Storey
DOC - Permit Expired12/21/200912/22/200912/22/2009APASS
DetailsJim Storey
expired
MIS-Aging Inspection10/20/200910/20/200910/20/2009 FAIL
DetailsJim Storey
outstanding isues with trades
MIS-Aging Inspection8/18/20098/18/20098/19/2009 FAIL
DetailsJim Storey
outstanding isues with trades
ELE-Conference6/17/20096/18/20096/19/2009ADONE
DetailsMike Kinnear
please call Wyatt when on way out to meet you//###-####//substandard renters complaint: insurance company said they need 20 amp circuit breakers so worried main service is not up to code and outlets shorting out. Correction Install all missing device covers (note the outlet & switch covers throughout the house.)
Note: the panel has 20 or 40 amp breakers installed now.
BLD-Conference6/17/20096/18/20096/18/2009APART
DetailsJim Storey
please call Wyatt when on way out to meet you//###-####//substandard renters complaint: insurance company said they need 20 amp circuit breakers, no stove, glass in 2 windows broken, bathroom floor water damage from bathtub, bathroom ceiling caving in, front door doesn't close properly, toilet needs wax ring, some of the heater vents don't have any ducting they go straight to the outside. filled out housing form and left two copies on site with tennent.
MEC-Conference6/18/20096/18/20096/18/2009PFAIL
DetailsBill VanDegrift
per bill vandergrift mec correction notice--- dryer vent must exhaust outside, duct system must terminate to a secured floor registor.
PLM-Conference6/17/20096/18/20096/18/2009AFAIL
DetailsBill VanDegrift
please call Wyatt when on way out to meet you//###-####//substandard renters complaint:bathroom floor water damage from bathtub leaking, toilet needs wax ring, some of the heater vents don't have any ducting they go straight to the outside plumbing correction notice--- secure toilet to drainage connection, where water service connections are installed for a clotheswasher, an approved method of waste disposal hall be provided.
Application received  6/17/2009  
Issue Misc Permit............  6/17/2009 DONE
DetailsTisha Gallop