MIS-Aging Inspection | 6/15/2015 | 6/15/2015 | 6/15/2015 | | DONE |
Phil Shearer
|
|
|
|
DOC - Permit Finaled | 6/15/2015 | 6/15/2015 | 6/15/2015 | P | PASS |
Phil Shearer
|
|
|
|
MIS-Aging Inspection | 3/5/2015 | 3/5/2015 | 3/5/2015 | | DONE |
Bob Archibald
|
|
|
|
MIS-Aging Inspection | 11/25/2014 | 11/25/2014 | 11/25/2014 | | DONE |
Bob Archibald
|
|
|
Associated permits finaled
|
PLM-Final | 8/26/2014 | 8/26/2014 | 8/26/2014 | A | PASS |
Jim Johnson
|
|
|
Rob ###-####-please call if you can't make it it today
|
MEC-Final | 8/26/2014 | 8/26/2014 | 8/26/2014 | A | PASS |
Chad Schwendiman
|
|
|
Rob ###-####-please call if you can't make it it today - THEY ARE REMOVING THE DISHWASHER AND WASHING DISHES BY HAND UNTIL THEY CAN AFFORD A NEW SETUP. PER TIM WOODARD, AND TROY JAMES, NO MAKE UP AIR WILL BE REQUIRED FOR THE EXISTING CLASS 1 HOOD.
|
PLM-Conference | 8/21/2014 | 8/22/2014 | 8/22/2014 | P | PART |
Jim Johnson
|
|
|
Rob Phone #: ###-#### need main double check tested and certified need to install p-trap on prep sink
|
MEC-Conference | 8/22/2014 | 8/22/2014 | 8/22/2014 | P | FAIL |
Chad Schwendiman
|
|
|
Rob - ###-#### - NEED TO INSTALL STAINLESS 18" ON ALL DIDES OF THE CLASS 1 HOOD. NEED TO REMOVE INSULATION FROM COMBUSTION AIR OPENING FOR WATER HEATER. NEED CLASS 2 HOOD OVER DISHWASHER OR GET A LOW CONDENSING DISH WASHER, OR REMOVE DISH WASHER
|
Issue Misc Permit............ | | | 8/7/2014 | | DONE |
|
|
|
|
Application received | | | 1/3/2013 | | |
|
|
|
|