Permit NumberMIS14-00097
StatusFinaled
Name BECKWITH FAMILY TRUST
Site Address 1211 S OWYHEE AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
complaint complete remodel inside includeing elec, plm, mech. Changed utility room into bathroom and moved utility room to basement, kitchen remodel changed flat ceiling to vaulted ceiliing. Electrical concerns with grounding/safety.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
MIS-Aging Inspection8/19/20148/19/20148/20/2014 DONE
DetailsTony Young
DOC - Permit Finaled8/20/20148/20/20148/20/2014PPASS
DetailsTony Young
permits issued
ELE-Conference5/6/20145/7/20145/7/2014ADONE
DetailsRock A. Hudson
complaint doing work without permit; remodel inside including elec, plm, mech. Changed utility room into bathroom and moved utility room to basement, kitchen remodel changed flat ceiling to vaulted ceiliing. Electrical concerns with grounding/safety. Elecgtrical contractor to go through house, secure permit, install proper devices on ungrounded circuits, install tamper resistant recepticals wher changed on grounded circuits, install spark rings where needed, install peninsula receptical, GFCI kitchen counter recepticals, remove flexible cord behind fireplace up high, and check for 15 amp wire install on 20 amp breaker for kitchen lighting
BLD-Conference5/6/20145/7/20145/7/2014AFAIL
DetailsTom Arcoraci
complaint doing work without permit; remodel inside including elec, plm, mech. Changed utility room into bathroom and moved utility room to basement, kitchen remodel changed flat ceiling to vaulted ceiliing. Electrical concerns with appears to have removed false drop ceiling did not touch struc framing needs permit for laundry room framing sheet rocked over lath and plaster ceilings ok. un permitted additions done years ago
MEC-Conference5/6/20145/7/20145/6/2014PFAIL
DetailsBill VanDegrift
complaint doing work without permit; remodel inside including elec, plm, mech. Changed utility room into bathroom and moved utility room to basement, kitchen remodel changed flat ceiling to vaulted ceiliing. Electrical concerns with grounding/safety.
1) tune up dryer vent
2) complete gas piping upgrades and test
3) install b-vent from furnace and water heater for clearances
4) check combustion air for furnace and water heater
5) permit all mechanical work
PLM-Conference5/6/20145/7/20145/6/2014AFAIL
DetailsBill VanDegrift
complaint doing work without permit; remodel inside including elec, plm, mech. Changed utility room into bathroom and moved utility room to basement, kitchen remodel changed flat ceiling to vaulted ceiliing. Electrical concerns with grounding/safety.
1) trap and vent washer box
2) vent lav behind the washer box
3)weep hole required on water heater t&p
4)install directional fitting in 3" waste line in basement ceiling by bath
5) permit allplumbing work
Application received  5/6/2014  
Issue Misc Permit............  5/6/2014 DONE