MIS-Aging Inspection | 10/19/2015 | 10/19/2015 | 10/19/2015 | | DONE |
Jim Storey
|
|
|
|
DOC - Permit Expired | 10/19/2015 | 10/19/2015 | 10/19/2015 | P | DONE |
Jim Storey
|
|
|
new tennet working for occ
|
MEC-Conference | 7/20/2015 | 7/20/2015 | 7/20/2015 | A | PART |
Bill VanDegrift
|
|
|
talked to owner, he said Franco's has closed the doors and is squatting.
|
MEC-Conference | 4/29/2015 | 4/29/2015 | 4/29/2015 | P | PART |
Bill VanDegrift
|
|
|
Fred came into the office today to talk about what he needed if he changed contractors. If he could use the same design minus some equipment etc. I told him he needed to submit the plans he had for review and approval or he would need another design to submit for review and approval. No plans have been submitted for review at this time.
|
MEC-Conference | 4/22/2015 | 4/22/2015 | 4/22/2015 | P | NR |
Bill VanDegrift
|
|
|
went by for the plumbing inspection, no mechanical work has been done at this time. I have heard from Russ the contractor and he has been working on a design, there is some confusion about the design between the contractor and owner. design requires make up air. I asked Russ to submit the plans for review, no plans have been submitted at ths time.
|
PLM-Conference | 4/22/2015 | 4/22/2015 | 4/22/2015 | P | PART |
Bill VanDegrift
|
|
|
1) needs air gap at the ice bi drain at the bar 2) needs to test the premis dcva
|
MEC-Conference | 4/17/2015 | 4/17/2015 | 4/17/2015 | A | PART |
Bill VanDegrift
|
|
|
BS&R called saying they had the hood exhaust system almost complete but said the tenant told him he didnt need the makeup air unit. I told him we hadn't recieved a plan for review and approval or a permit and that the makeup air side would be required. I am unaware of any agreement to delete the makeup air side.
|
PLM-Conference | 3/5/2015 | 3/6/2015 | 3/6/2015 | A | PART |
Bill VanDegrift
|
|
|
10:30 went over the corrections with Fred. there is an air gap on the dishwasher, ice maker at bar needs a drain for the ice bin and verify air gap inside, disconnect the ice mechine by dish washing area will not be used., disconnect the water to the prewash sink disposal rinse there is no disposal to need it.. run t& p and permit the water heater with other work.
|
Case Summary | | | 3/4/2015 | | DONE |
|
|
|
|
PLM-Conference | 12/16/2014 | 12/16/2014 | 12/16/2014 | A | FAIL |
Bill VanDegrift
|
|
|
plumbing corrections have not been made
|
MEC-Conference | 12/15/2014 | 12/15/2014 | 12/15/2014 | A | PART |
Bill VanDegrift
|
|
|
meeting on site. The tenant will provide a design for review with in 30 days showing a type two hood over the doors of the pizza oven, two new up flow exhaust fans on the roof for the existing type one hood. Will address make up air requirements for the new system, and verify the new water heater is drafting properly.
|
MEC-Conference | 12/15/2014 | 12/15/2014 | 12/15/2014 | A | PASS |
Dixie Fellows
|
|
|
10am..they will hire an engineer to draw up a plan to address the correction notice left by Chad. Jenifer will give them 60 days to complete the job.
|
MEC-Conference | 12/12/2014 | 12/12/2014 | 12/9/2014 | A | FAIL |
Bill VanDegrift
|
|
|
emailed Russ that the hood needed to extend 6" beyond the appliance to capture heat and moisture from the oven
|
MEC-Conference | 12/12/2014 | 12/12/2014 | 12/4/2014 | A | FAIL |
Bill VanDegrift
|
|
|
Russ sent over submittal information for a hood that was being concidered for installation asking if it would be code compliant. I sent it to Troy for review. With the information we were given the oven would not be code compliant installed under the existing hood because the hood would not extend beyond the oven by the min. six inches. We did not receive any information about additional clearances required for the equipment. Back, sides, etc.
|
MEC-Conference | 12/12/2014 | 12/12/2014 | 12/1/2014 | A | FAIL |
Bill VanDegrift
|
|
|
Russ sent information for a new hood for us to review,I sent it to troy James to review, I asked what their plan was, where the hood was going, replacing existing, leaving the original hood, relocating the oven. The reply was that he didn't know what they were going to do.
|
MEC-Conference | 12/12/2014 | 12/12/2014 | 11/19/2014 | A | FAIL |
Bill VanDegrift
|
|
|
I never heard anything else from Drake so I dropped in to see if anything had been done, nothing had been done, didn't talk to Fred or Richard. I got a call from Russ from BSR,an equipment supplier, he said he has been working with Franco's to find a solution for their problem. I asked him how long he had been working with them, he said sense yesterday. he said he was having a meeting the next day with France's and would let me know what they came up with.
|
PLM-Conference | 10/29/2014 | 10/29/2014 | 10/29/2014 | P | FAIL |
Bill VanDegrift
|
|
|
stopped by to verify the stainless is installed behing the hood. the stainless is attached to the wood studs. I did have a call from edddie with Drake mechanical today saying that Franco's had contacted them about a hood design, he didn't know what the outcome of that conversation was and Rick Hazard was out of town. The owner is still talking about replacing the hood system.
|
MEC-Conference | 10/21/2014 | 10/21/2014 | 10/20/2014 | P | DONE |
Bill VanDegrift
|
|
|
Fred called 10/20/14 saying he was needing information from the owner about how much makeup air was going to be supplied so his contractor could design a new hood system. I told him he needed to have his contractor contact us so we could give him the information he needed to provide us if they were going to install a new hood system. he said the wood framing at the existing hood had been removed and replaced with the stainless to match the existing.
10/21/14 recieved a call from Greg the owner saying he had his contractor ready to provide the required makeup air for the existing hood. He had talked to the tenants and said they didn't mention any issues about the hood.
|
MEC-Conference | 10/14/2014 | 10/14/2014 | 10/10/2014 | A | FAIL |
Bill VanDegrift
|
|
|
no corrections made forwarded to legal for service termination
|
MEC-Conference | 10/9/2014 | 10/9/2014 | 10/9/2014 | P | FAIL |
Chad Schwendiman
|
|
|
Follow up - no corrections have been made
|
MEC-Conference | 10/14/2014 | 10/14/2014 | 10/1/2014 | A | FAIL |
Bill VanDegrift
|
|
|
no corrections made, left correction notice with 7 days to comply with hood and equipment requirements.
|
MEC-Conference | 9/25/2014 | 9/25/2014 | 9/26/2014 | P | CANC |
Bill VanDegrift
|
|
|
|
MEC-Conference | 9/25/2014 | 9/26/2014 | 9/26/2014 | P | FAIL |
Chad Schwendiman
|
|
|
Meet contractor at 1:00pm - me and Bill met the owners and Ed Hanson onsite to go over corrections
|
MEC-Conference | 9/23/2014 | 9/26/2014 | 9/25/2014 | A | CANC |
Chad Schwendiman
|
|
|
Follow up and get with bill if no contact has been made from owner
|
PLM-Conference | 9/16/2014 | 9/23/2014 | 9/24/2014 | A | PASS |
Eric Strole
|
|
|
Hired payless plumbing to do work.
|
MIS-Aging Inspection | 9/16/2014 | 9/23/2014 | 9/23/2014 | A | FAIL |
Chad Schwendiman
|
|
|
FOLLOW UP - went and talked with the manager. he is suppose to contact me this week & schedule a time for me to meet with a hvac contractor on site.
|
MIS-Aging Inspection | 9/15/2014 | 9/15/2014 | 9/16/2014 | P | FAIL |
Chad Schwendiman
|
|
|
Rich Franco Phone #: ###-#### - NO CORRECTIONS HAVE BEEN MADE. LEFT CORRECTION NOTICE ON SITE.
|
MIS-Aging Inspection | 9/15/2014 | 9/15/2014 | 9/16/2014 | P | FAIL |
Eric Strole
|
|
|
Rich Franco Phone #: ###-####Left correction notice.
|
MEC-Conference | 9/12/2014 | 9/15/2014 | 9/15/2014 | P | DEFR |
Jim Storey
|
|
|
Rich Franco Phone #: ###-####
|
PLM-Conference | 9/12/2014 | 9/15/2014 | 9/15/2014 | P | DEFR |
Jim Storey
|
|
|
Rich Franco Phone #: ###-####
|
MEC-Conference | 7/7/2014 | 7/8/2014 | 7/8/2014 | A | FAIL |
Chad Schwendiman
|
|
|
After 10 am please-Fred***For Occupancy Phone #: ###-#### - Class 1 hood needs to extend 6" beyond the cooking equipment, currently the cooking equipment extends out past the hood. Grease duct for class 1 hood is not ran in approved material, needs to be changed out to meet code. Need stainless steel between class 1 hood & wall, on wall under hood, stainless steel needs to extend 18" out from edge of class 1 hood. Need make-up air for class 1 hood. Need econmizer for roof top unit. Need to support gas pipe on roof. Any exhaust or plumbing vents need to terminate 10' away or 3' above fresh air openings when make-up air, and economizer are installed.
|
PLM-Conference | 7/7/2014 | 7/8/2014 | 7/8/2014 | A | FAIL |
Eric Strole
|
|
|
After 10 am please-Fred***For Occupancy Phone #: ###-####-Need to run T&P to an approved location. Need a rpba on the dishwasher and the carbonator, dbca on the ice machine and all backflows need tested and certified. When all equipment is installed more devices may be required.
|
Application received | | | 7/7/2014 | | |
|
|
|
|
Issue Misc Permit............ | | | 7/7/2014 | | DONE |
Barbara Stitt
|
|
|
|