PLM-Final | 4/30/2015 | 4/30/2015 | 4/30/2015 | P | PART |
Bill VanDegrift
|
|
|
plm and mec permit I went ahead and doc finaled this permit
|
DOC - Permit Finaled | 4/30/2015 | 4/30/2015 | 4/30/2015 | P | PASS |
Bill VanDegrift
|
|
|
plm and mec permit
|
MIS-Aging Inspection | 4/30/2015 | 4/30/2015 | 4/30/2015 | | DEFR |
Jim Storey
|
|
|
plm mec
|
MIS-Aging Inspection | 1/29/2015 | 1/29/2015 | 1/29/2015 | | DEFR |
Eric Strole
|
|
|
380
|
MEC-Final | 10/28/2014 | 10/29/2014 | 10/29/2014 | A | PASS |
Chad Schwendiman
|
|
|
for occupancy // Brad TAylor Phone #: ###-####
|
PLM-Final | 10/28/2014 | 10/29/2014 | 10/29/2014 | A | PASS |
Eric Strole
|
|
|
for occupancy // Brad TAylor Phone #: ###-####
|
MEC-Final | 10/27/2014 | 10/28/2014 | 10/28/2014 | P | CANC |
Chad Schwendiman
|
|
|
|
MEC-Conference | 10/27/2014 | 10/27/2014 | 10/27/2014 | P | FAIL |
Chad Schwendiman
|
|
|
Need to install metal 18" out past the edge of the class 1 hood
|
PLM-Final | 10/24/2014 | 10/27/2014 | 10/27/2014 | A | FAIL |
Eric Strole
|
|
|
Brad Phone #: ###-####-1-Need to install a dbca on water supply. 2-Need a thermal expantion tank. 3-T&P needs to drain down to mop sink and cannot use a water heater flex. 4-Need to install a rpba on dishwasher. 5-Need a rpba on soap dispensor or get one with an airgap and needs it own water sypply. 6-Ice machine when installed may requie a backflow device. 7-Prep sink needs to drain to flr sink and all sinks need to be piped with dwv fittings. 8-All backflows need tested and certified.
|
Application received | | | 10/9/2014 | | |
|
|
|
|
Issue Misc Permit............ | | | 10/9/2014 | | DONE |
|
|
|
MIS for Mechanical and Plumbing
|