Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberMIS14-00245
StatusFinaled
Name BRAD TAYLOR
Site Address 930 S VISTA AVE
Project Name(BBQ 4 LIFE)(VISTA VILLAGE)
Customer Number 
ePlanReviewNo
Description
MIS Case for Mechanical and Plumbing
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
PLM-Final4/30/20154/30/20154/30/2015PPART
DetailsBill VanDegrift
plm and mec permit I went ahead and doc finaled this permit
DOC - Permit Finaled4/30/20154/30/20154/30/2015PPASS
DetailsBill VanDegrift
plm and mec permit
MIS-Aging Inspection4/30/20154/30/20154/30/2015 DEFR
DetailsJim Storey
plm mec
MIS-Aging Inspection1/29/20151/29/20151/29/2015 DEFR
DetailsEric Strole
380
MEC-Final10/28/201410/29/201410/29/2014APASS
DetailsChad Schwendiman
for occupancy // Brad TAylor Phone #: ###-####
PLM-Final10/28/201410/29/201410/29/2014APASS
DetailsEric Strole
for occupancy // Brad TAylor Phone #: ###-####
MEC-Final10/27/201410/28/201410/28/2014PCANC
DetailsChad Schwendiman
MEC-Conference10/27/201410/27/201410/27/2014PFAIL
DetailsChad Schwendiman
Need to install metal 18" out past the edge of the class 1 hood
PLM-Final10/24/201410/27/201410/27/2014AFAIL
DetailsEric Strole
Brad Phone #: ###-####-1-Need to install a dbca on water supply. 2-Need a thermal expantion tank. 3-T&P needs to drain down to mop sink and cannot use a water heater flex. 4-Need to install a rpba on dishwasher. 5-Need a rpba on soap dispensor or get one with an airgap and needs it own water sypply. 6-Ice machine when installed may requie a backflow device. 7-Prep sink needs to drain to flr sink and all sinks need to be piped with dwv fittings. 8-All backflows need tested and certified.
Application received  10/9/2014  
Issue Misc Permit............  10/9/2014 DONE
MIS for Mechanical and Plumbing